AHRI SYSTEM MATCHES
Model No.
Cooling
Capacity
SEER EER
Heat Capacity Heat COP
HSPF
(IV)
Coil or
Air Handler
Furnace
AHRI
Reference
High Low High Low
XP17-042-230 40,000 15.00 12.20 35,400 22,200 3.24 2.50 8.70 C33-49 EL195UH110XE60C 4693646
XP17-042-230 40,000 15.00 12.20 35,400 22,200 3.22 2.52 8.70 C33-49 EL296UH090XV36C 5054808
XP17-042-230 40,000 15.20 12.20 35,400 22,000 3.24 2.50 8.70 C33-49 EL296UH090XV48C 5054809
XP17-042-230 40,000 15.20 12.50 35,200 22,000 3.24 2.52 8.70 C33-49 EL296UH090XV60C 5054810
XP17-042-230 40,000 15.20 12.20 35,400 22,200 3.26 2.54 8.70 C33-49 EL296UH110V48C 4894969
XP17-042-230 40,000 15.20 12.50 35,400 22,000 3.26 2.52 8.70 C33-49 EL296UH110XV60C 5054811
XP17-042-230 40,000 15.20 12.50 35,200 22,000 3.24 2.52 8.70 C33-49 ML180UH090E60C 4669923
XP17-042-230 40,000 15.20 12.50 35,200 22,000 3.22 2.52 8.70 C33-49 ML180UH110E60C 4669924
XP17-042-230 40,000 15.20 12.50 35,200 22,000 3.22 2.52 8.70 C33-49 ML180UH110XE60C 4672141
XP17-042-230 39,500 15.50 12.50 35,000 21,800 3.24 2.54 8.70 C33-49 SL280UH090V60C 3894781
XP17-042-230 39,500 15.50 12.50 35,000 21,800 3.24 2.54 8.70 C33-49 SL280UH090XV60C 4235860
XP17-042-230 40,500 15.20 12.70 35,400 22,000 3.28 2.54 8.70 C33-49 SL280UH110V60C 3894782
XP17-042-230 40,500 15.20 12.70 35,400 22,000 3.28 2.54 8.70 C33-49 SL280UH110XV60C 4042008
XP17-042-230 40,000 15.00 12.20 35,400 22,200 3.22 2.52 8.70 C33-49 SLP98UH090XV36C 5137359
XP17-042-230 40,000 15.20 12.20 35,400 22,000 3.24 2.50 8.70 C33-49 SLP98UH090XV48C 5137360
XP17-042-230 40,000 15.20 12.50 35,200 22,000 3.24 2.52 8.70 C33-49 SLP98UH090XV60C 5137361
XP17-042-230 40,000 15.20 12.50 35,400 22,000 3.26 2.52 8.70 C33-49 SLP98UH110XV60C 5137362
XP17-042-230 39,500 14.00 11.50 36,000 22,800 3.10 2.40 8.50 C33-49 3840107
XP17-042-230 38,000 14.70 12.00 34,800 22,000 3.24 2.40 8.50 C33-50/60C EL195UH090XE48C 4693647
XP17-042-230 38,500 14.70 12.00 35,200 22,200 3.30 2.44 8.50 C33-50/60C EL195UH110XE60C 4693648
XP17-042-230 38,500 14.50 12.00 35,200 22,200 3.26 2.40 8.50 C33-50/60C EL296UH090XV36C 5054812
XP17-042-230 38,500 14.70 12.20 35,200 22,200 3.30 2.44 8.50 C33-50/60C EL296UH090XV48C 5054813
XP17-042-230 38,500 14.70 12.20 34,800 22,000 3.24 2.42 8.50 C33-50/60C EL296UH090XV60C 5054814
XP17-042-230 38,500 14.70 12.00 35,200 22,200 3.30 2.44 8.50 C33-50/60C EL296UH110V48C 4894970
XP17-042-230 38,500 14.70 12.00 35,200 22,200 3.30 2.44 8.50 C33-50/60C EL296UH110XV60C 5054815
XP17-042-230 38,500 15.00 12.20 35,000 22,000 3.30 2.44 8.50 C33-50/60C ML180UH090E60C 4669925
XP17-042-230 38,500 14.70 12.20 34,800 22,000 3.28 2.44 8.50 C33-50/60C ML180UH110E60C 4669926
XP17-042-230 38,500 14.70 12.20 34,800 22,000 3.28 2.44 8.50 C33-50/60C ML180UH110XE60C 4672145
XP17-042-230 38,000 15.00 12.20 34,600 21,800 3.26 2.44 8.50 C33-50/60C SL280UH090V60C 3894783
XP17-042-230 38,000 15.00 12.20 34,600 21,800 3.26 2.44 8.50 C33-50/60C SL280UH090XV60C 4235861
XP17-042-230 38,500 14.50 12.00 35,200 22,200 3.26 2.40 8.50 C33-50/60C SLP98UH090XV36C 5137363
XP17-042-230 38,500 14.70 12.20 35,200 22,200 3.30 2.44 8.50 C33-50/60C SLP98UH090XV48C 5137364
XP17-042-230 38,500 14.70 12.20 34,800 22,000 3.24 2.42 8.50 C33-50/60C SLP98UH090XV60C 5137365
XP17-042-230 38,500 14.70 12.00 35,200 22,200 3.30 2.44 8.50 C33-50/60C SLP98UH110XV60C 5137366
XP17-042-230 38,000 13.70 11.20 35,800 22,800 3.18 2.34 8.20 C33-50/60C 3840118
XP17-042-230 40,000 15.50 12.70 36,200 22,600 3.60 2.58 9.20 CBX27UH-042 3840018
XP17-042-230 40,000 15.20 12.70 36,400 22,600 3.60 2.58 9.20 CBX27UH-048 3840019
XP17-042-230 39,500 14.70 12.20 36,600 23,000 3.50 2.52 9.00 CBX32M-048 3840020
XP17-042-230 40,000 15.70 12.70 36,200 22,600 3.62 2.60 9.20 CBX32MV-048 3840015
XP17-042-230 39,500 15.20 12.70 36,000 22,600 3.54 2.56 9.00 CBX40UHV-042 3840016
XP17-042-230 40,000 15.50 12.70 36,200 22,600 3.60 2.60 9.20 CBX40UHV-048 3840017
XP17-042-230 38,500 14.70 12.20 35,000 22,000 3.28 2.42 8.50 CH33-43 EL195UH090XE48C 4693631
XP17-042-230 39,000 14.70 12.20 35,200 22,400 3.34 2.46 8.70 CH33-43 EL195UH110XE60C 4693632
XP17-042-230 39,000 14.20 11.70 35,800 22,600 3.32 2.40 8.50 CH33-43 EL296UH070XV36B 5054779
XP17-042-230 38,500 14.70 12.20 35,200 22,200 3.32 2.44 8.50 CH33-43 EL296UH090XV36C 5054780
XP17-042-230 39,000 15.00 12.20 35,200 22,200 3.34 2.46 8.70 CH33-43 EL296UH090XV48C 5054781
XP17-042-230 38,500 15.00 12.20 34,800 22,000 3.30 2.46 8.50 CH33-43 EL296UH090XV60C 5054782
XP17-042-230 39,000 15.00 12.20 35,200 22,200 3.36 2.48 8.70 CH33-43 EL296UH110XV60C 5054783
XP17-042-230 39,000 15.00 12.20 35,400 22,400 3.36 2.48 8.70 CH33-43 ML180UH090E48B 4666899
XP17-042-230 39,000 15.00 12.20 35,200 22,000 3.34 2.44 8.70 CH33-43 ML180UH090E60C 4666900
NOTES:
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines);
• Cooling Ratings - 95°F outdoor air temperature and 80 °F db/67° F wb entering indoor coil air.
• High Temperature Heating Ratings - 47° F db/43° F wb outdoor air temperature and 70 °F db entering indoor coil air.
• Low Temperature Heating Ratings - 17 °F db/15° F wb outdoor air temperature and 70 °F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used
(order separately).
To convert HSPF from Region IV to Region V - Divide by 1.15.