XP17 - 2 to 5 Ton Heat Pump / Page 31
AHRI SYSTEM MATCHES
Model No.
Cooling
Capacity
SEER EER
Heat Capacity Heat COP
HSPF
(IV)
Coil or
Air Handler
Furnace
AHRI
Reference
High Low High Low
XP17-042-230 39,000 15.00 12.20 35,400 22,400 3.36 2.48 8.70 CH33-43 ML180UH090XE48B 4671994
XP17-042-230 38,500 15.00 12.20 35,000 22,000 3.32 2.44 8.50 CH33-43 ML180UH110E60C 4666901
XP17-042-230 38,500 15.00 12.20 35,000 22,000 3.32 2.44 8.50 CH33-43 ML180UH110XE60C 4672125
XP17-042-230 39,000 14.20 11.70 35,800 22,600 3.32 2.40 8.50 CH33-43 SLP98UH070XV36B 5136910
XP17-042-230 38,500 14.70 12.20 35,200 22,200 3.32 2.44 8.50 CH33-43 SLP98UH090XV36C 5136911
XP17-042-230 39,000 15.00 12.20 35,200 22,200 3.34 2.46 8.70 CH33-43 SLP98UH090XV48C 5136912
XP17-042-230 38,500 15.00 12.20 34,800 22,000 3.30 2.46 8.50 CH33-43 SLP98UH090XV60C 5136913
XP17-042-230 39,000 15.00 12.20 35,200 22,200 3.36 2.48 8.70 CH33-43 SLP98UH110XV60C 5136914
XP17-042-230 39,500 14.70 12.20 35,600 22,400 3.40 2.48 8.70 CH33-43B SL280UH090V36B 3894784
XP17-042-230 39,000 15.00 12.20 35,400 22,200 3.38 2.46 8.70 CH33-43B SL280UH090V48B 3894785
XP17-042-230 39,000 15.00 12.20 35,400 22,200 3.38 2.46 8.70 CH33-43B SL280UH090XV48B 4041798
XP17-042-230 39,000 14.00 11.70 36,000 22,800 3.26 2.38 8.50 CH33-43B 3840129
XP17-042-230 39,000 15.00 12.20 35,200 22,200 3.36 2.46 8.70 CH33-43C EL296UH110V48C 4894975
XP17-042-230 38,500 15.20 12.50 34,600 21,800 3.32 2.46 8.70 CH33-43C SL280UH090V60C 3894786
XP17-042-230 38,500 15.20 12.50 34,600 21,800 3.32 2.46 8.70 CH33-43C SL280UH090XV60C 4235864
XP17-042-230 39,000 15.20 12.50 35,200 22,000 3.38 2.46 8.70 CH33-43C SL280UH110V60C 3894787
XP17-042-230 39,000 15.20 12.50 35,200 22,000 3.38 2.46 8.70 CH33-43C SL280UH110XV60C 4042011
XP17-042-230 38,500 13.70 11.50 35,800 22,800 3.18 2.34 8.20 CH33-43C 3840133
XP17-042-230 38,000 14.00 11.50 35,600 22,600 3.26 2.40 8.50 CH33-44/48 EL296UH070XV36B 5054784
XP17-042-230 38,000 14.50 12.00 35,400 22,200 3.34 2.44 8.70 CH33-44/48 ML180UH090E48B 4666902
XP17-042-230 38,000 14.50 12.00 35,400 22,200 3.34 2.44 8.70 CH33-44/48 ML180UH090XE48B 4671995
XP17-042-230 38,500 14.50 12.00 35,400 22,400 3.36 2.46 8.70 CH33-44/48 SL280UH090V36B 3894788
XP17-042-230 38,000 14.70 12.00 35,200 22,200 3.34 2.46 8.70 CH33-44/48 SL280UH090V48B 3894789
XP17-042-230 38,000 14.70 12.00 35,200 22,200 3.34 2.46 8.70 CH33-44/48 SL280UH090XV48B 4041799
XP17-042-230 38,000 14.00 11.50 35,600 22,600 3.26 2.40 8.50 CH33-44/48 SLP98UH070XV36B 5136915
XP17-042-230 38,000 13.70 11.20 36,000 22,800 3.24 2.36 8.20 CH33-44/48 3840144
XP17-042-230 38,500 14.50 12.00 35,200 22,200 3.26 2.40 8.50 CH33-48 EL296UH090XV36C 5054785
XP17-042-230 38,500 14.70 12.20 35,200 22,200 3.30 2.44 8.50 CH33-48 EL296UH090XV48C 5054786
XP17-042-230 38,500 14.70 12.20 35,000 22,000 3.28 2.42 8.50 CH33-48 EL296UH090XV60C 5054787
XP17-042-230 38,500 14.70 12.00 35,200 22,200 3.30 2.44 8.50 CH33-48 EL296UH110XV60C 5054788
XP17-042-230 38,500 15.00 12.20 35,000 22,000 3.32 2.44 8.70 CH33-48 ML180UH090E60C 4666903
XP17-042-230 38,500 14.70 12.20 35,000 22,000 3.30 2.44 8.50 CH33-48 ML180UH110E60C 4666904
XP17-042-230 38,500 14.70 12.20 35,000 22,000 3.30 2.44 8.50 CH33-48 ML180UH110XE60C 4672126
XP17-042-230 38,000 15.00 12.20 34,800 21,800 3.28 2.44 8.50 CH33-48 SL280UH090V60C 3894790
XP17-042-230 38,000 15.00 12.20 34,800 21,800 3.28 2.44 8.50 CH33-48 SL280UH090XV60C 4235865
XP17-042-230 38,500 14.70 12.20 35,200 22,200 3.32 2.46 8.50 CH33-48 SL280UH110V60C 3894791
XP17-042-230 38,500 14.70 12.20 35,200 22,200 3.32 2.46 8.50 CH33-48 SL280UH110XV60C 4042012
XP17-042-230 38,500 14.50 12.00 35,200 22,200 3.26 2.40 8.50 CH33-48 SLP98UH090XV36C 5136916
XP17-042-230 38,500 14.70 12.20 35,200 22,200 3.30 2.44 8.50 CH33-48 SLP98UH090XV48C 5136917
XP17-042-230 38,500 14.70 12.20 35,000 22,000 3.28 2.42 8.50 CH33-48 SLP98UH090XV60C 5136918
XP17-042-230 38,500 14.70 12.00 35,200 22,200 3.30 2.44 8.50 CH33-48 SLP98UH110XV60C 5136919
XP17-042-230 38,000 13.70 11.20 35,800 22,800 3.18 2.36 8.20 CH33-48 3840148
XP17-042-230 38,000 14.70 12.00 35,000 22,000 3.26 2.42 8.50 CH33-48C EL195UH090XE48C 4693633
XP17-042-230 38,500 14.70 12.00 35,200 22,200 3.32 2.44 8.50 CH33-48C EL195UH110XE60C 4693634
XP17-042-230 38,500 14.70 12.00 35,200 22,200 3.30 2.44 8.50 CH33-48C EL296UH110V48C 4894976
XP17-042-230 39,500 15.20 12.50 35,200 22,200 3.22 2.40 8.50 CH33-49 EL195UH090XE48C 4693635
XP17-042-230 40,000 15.20 12.50 35,600 22,400 3.26 2.42 8.50 CH33-49 EL195UH110XE60C 4693636
XP17-042-230 40,000 15.00 12.50 35,600 22,400 3.24 2.40 8.50 CH33-49 EL296UH090XV36C 5054789
XP17-042-230 40,000 15.20 12.50 35,400 22,200 3.24 2.40 8.50 CH33-49 EL296UH090XV48C 5054790
XP17-042-230 39,500 15.20 12.50 35,200 22,000 3.22 2.40 8.50 CH33-49 EL296UH090XV60C 5054791
NOTES:
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines);
• Cooling Ratings - 95°F outdoor air temperature and 80 °F db/67° F wb entering indoor coil air.
• High Temperature Heating Ratings - 47° F db/43° F wb outdoor air temperature and 70 °F db entering indoor coil air.
• Low Temperature Heating Ratings - 17 °F db/15° F wb outdoor air temperature and 70 °F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used
(order separately).
To convert HSPF from Region IV to Region V - Divide by 1.15.