Do you have a question about the Lenovo NE1032 and is the answer not in the manual?
Rack Units | 1U |
---|---|
Product Type | Switch |
Form Factor | Rack-mountable |
Jumbo Frame Support | Yes |
Input Voltage | 100-240 VAC |
Storage Temperature | -40°C to 70°C |
Operating Humidity | 10% to 90% non-condensing |
Storage Humidity | 5% to 95% non-condensing |
Power Supply | Dual, hot-swappable, redundant power supplies |
Jumbo Frame Size | 9216 bytes |
Dimensions (W x D x H) | 440 x 440 x 44 mm |
Operating Temperature | 0°C to 40°C |
Switching Capacity | 6.4 Tbps |
Forwarding Rate | 476 Mpps |
Lists prerequisites for the guide, including software version and terminal emulation program.
Explains how to connect via SSH using default credentials after obtaining the IP address.
Details connecting via a terminal emulator using a USB adapter and console settings.
Explains the difference between unprivileged and privileged modes and how to enter privileged mode.
Describes global configuration mode and interface configuration mode for switch settings.
Provides CLI commands to set the IP address for the management interface.
Shows how to configure management IP using a VLAN interface.
Instructions for downloading and preparing the firmware file for update.
Details the SFTP copy process and expected output during firmware installation.
Instructs to reload the switch to apply the newly installed firmware.
Configures the password for entering privileged EXEC mode.
Steps to generate RSA SSH keys and set login attempt limits.
Configures authentication, authorization, and accounting for login attempts.
Creates network-admin and network-operator user accounts with passwords.
Configures the Network Time Protocol server for time synchronization.
Configures the Domain Name System server for name resolution.
Instructions for creating VLANs individually or in a range.
Shows how to verify spanning tree protocol configuration, defaulting to rapid-pvst.
Sets up local logging to a file with debug level and maximum size.
Configures logging to a remote syslog server via TCP.
Configures a port for single VLAN access, suitable for end devices.
Configures a port for multiple VLANs, supporting tagged and untagged traffic.
Configures a port for carrying multiple VLANs using trunking.
Enables LLDP transmission, reception, and trap notifications on an interface.
Commands to display information about neighboring network devices using LLDP.
Provides an email address for submitting feedback on the documentation.
Links to online resources for technical support and documentation.
States that switches are not covered by the HC3 system warranty and directs configuration queries to the manufacturer.