Lenovo Storage S3200 with Fibre Channel
16
Both the commands we need for the next steps can be menu driven. There is a
verification step in between we can run to ensure that our settings are correct. The
commands we want to run are in the list below.
Ipaddrset
ping $IPADDRESS
firmwaredownload
o As a note, firmwaredownload is optional and for most environments may
not be required
Answer the menu driven prompts and you will have a switch that is ready to be
managed.
Zoning
The below are command examples for setting up a simple zoning configuration:
alicreate "Example_Alias_1", "xx:xx:xx:xx:xx:xx:xx:xx"
zonecreate "zone_Example_1", "Example_Alias_1; Stor_Example_Alias_1;
Stor_Example_Alias_2"
cfgcreate "lenovo","zone_Example_1; zone_Example_2; zone_Example_3"
cfgsave
cfgenable "lenovo”
Lenovo Storage S3200
By default, the S3200 has a static IP address configured which will be active unless
there is a DHCP assignment given to it. The default IP addresses are 10.0.0.2 and
10.0.0.3 with a /24 CIDR (255.255.255.0 netmask.) In an environment that has DHCP,
you can learn the IP assignment by checking the system logs or you can simply directly
attach an Ethernet cable to a server or laptop with an address assigned to the interface
such as 10.0.0.4 with a 255.255.255.0 netmask.
Once you can establish connectivity, there are two primary options of setting up the
storage. The option displayed in this guide is the web interface, but the CLI can achieve
the same result. See the Other Reading section for additional documentation including
the CLI reference guide.