Table 3. Events organized by severity (continued)
Event ID
Message String Severity
FQXSFMA0033M Intel Optane DCPMM persistent memory interleave set has [arg1]
DCPMMs(DIMM [arg2]), [arg3] DIMMs' location is not correct.
Warning
FQXSFMA0034M DIMM [arg1] (UID: [arg2]) of Intel Optane DCPMM persistent memory
interleave set should be moved to DIMM slot [arg3] in sequence.
Warning
FQXSFMA0035M Intel Optane DCPMM interleave set should have [arg1] DCPMMs, but
[arg2] DCPMMs are missing.
Warning
FQXSFMA0036M DIMM [arg1] (UID: [arg2]) of Intel Optane DCPMM persistent memory
interleave set is missing.
Warning
FQXSFMA0037G Intel Optane DCPMM interleave set (DIMM [arg1]) is migrated from
another system (Platform ID: [arg2]), these migrated DCPMMs are not
supported nor warranted in this system.
Warning
FQXSFMA0038K All Intel Optane DCPMMs could not be auto unlocked because of no
passphrase.
Warning
FQXSFMA0039K One or more Intel Optane DCPMMs could not be auto unlocked
because of invalid passphrase.
Warning
FQXSFMA0040K Invalid Intel Optane DCPMM configuration detected. Please verify
DCPMM configuration is valid.
Warning
FQXSFMA0041K Near Memory/Far Memory ratio (1:[arg1].[arg2]) for Intel Optane
DCPMM configuration is not in recommended range (1:2 - 1:16).
Warning
FQXSFMA0047M SPD CRC checking failed on DIMM [arg1]. [arg2]
Warning
FQXSFPU0021G Hardware physical presence is in asserted state. Warning
FQXSFPU0022G The TPM configuration is not locked. Warning
FQXSFPU0023G Secure Boot Image Verification Failure Warning. Warning
FQXSFPU0033G
Processor has been disabled. Warning
FQXSFPU0062F System uncorrected recoverable error happened in Processor [arg1]
Core [arg2] MC bank [arg3] with MC Status [arg4], MC Address [arg5],
and MC Misc [arg6].
Warning
FQXSFPU4033F TPM Firmware recovery is in progress. Please DO NOT power off or
reset system.
Warning
FQXSFPU4035M TPM Firmware recovery failed. TPM chip may be damaged. Warning
FQXSFPU4040M TPM selftest has failed. Warning
FQXSFPU4043G TPM Firmware update aborted. System is rebooting...
Warning
FQXSFPU4045G Physical Presence is not asserted, abort TPM Firmware upgrade. Warning
FQXSFPU4050G
Failed to update TPM Firmware. Warning
FQXSFPU4051G Undefined TPM_TCM_POLICY found
Warning
FQXSFPU4052G TPM_TCM_POLICY is not locked
Warning
FQXSFPU4053G System TPM_TCM_POLICY does not match the planar.
Warning
FQXSFPU4054G TPM/TCM card logical binding has failed.
Warning
FQXSFPW0001L CMOS has been cleared. Warning
156 ThinkSystem D2 Enclosure, Modular Enclosure, Modular Enclosure for 6U Configuration and ThinkSystem SD530 Compute
Node Messages and Codes Reference