EasyManua.ls Logo

Lenovo ThinkSystem D2 - List of UEFI events

Lenovo ThinkSystem D2
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 3. Events organized by severity (continued)
Event ID
Message String Severity
FQXSFSM0007I The XCC System Event log (SEL) is full. Informational
FQXSFSR0002I [arg1] GPT corruption recovered, DiskGUID: [arg2] Informational
FQXSFDD0001G DRIVER HEALTH PROTOCOL: Missing Configuration. Requires
Change Settings From F1.
Warning
FQXSFDD0002M DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller.
Warning
FQXSFDD0003I DRIVER HEALTH PROTOCOL: Reports 'Reboot' Required Controller. Warning
FQXSFDD0005M DRIVER HEALTH PROTOCOL: Disconnect Controller Failed. Requires
'Reboot'.
Warning
FQXSFDD0006M DRIVER HEALTH PROTOCOL: Reports Invalid Health Status Driver.
Warning
FQXSFDD0007G Security Key Lifecycle Manager (SKLM) IPMI Error.
Warning
FQXSFIO0008M
An intra-board UPI dynamic link width reduction has been detected
on the link between processor [arg1] port [arg2] and processor [arg3]
port [arg4].
Warning
FQXSFIO0009M
An inter-board UPI dynamic link width reduction has been detected
on the link between processor [arg1] port [arg2] and processor [arg3]
port [arg4].
Warning
FQXSFIO0013I The device found at Bus [arg1] Device [arg2] Function [arg3] could not
be configured due to resource constraints. The Vendor ID for the
device is [arg4] and the Device ID is [arg5]. The physical slot number
is [arg6].
Warning
FQXSFIO0016M
IFM: Reset loop avoided - Multiple resets not allowed. Warning
FQXSFIO0021J PCIe Error Recovery has occurred in physical [arg1] number [arg2].
The [arg3] may not operate correctly.
Warning
FQXSFIO0022J PCIe Link Width has degraded from [arg1] to [arg2] in physical [arg3]
number [arg4].
Warning
FQXSFIO0023J PCIe Link Speed has degraded from [arg1] to [arg2] in physical [arg3]
number [arg4].
Warning
FQXSFMA0012L The [arg1] PFA Threshold limit has been exceeded on DIMM [arg2] at
address [arg3]. [arg4]
Warning
FQXSFMA0016M Memory spare copy failed. [arg1]
Warning
FQXSFMA0026G Multi-bit CE occurred on DIMM [arg1], need to restart the system for
DIMM Self-healing to attempt post package repair (PPR)
Warning
FQXSFMA0027M DIMM [arg1] Self-healing, attempt post package repair (PPR) failed at
Rank [arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6].
[arg7]
Warning
FQXSFMA0028M DIMM [arg1] Self-healing, attempt post package repair (PPR)
exceeded DIMM level threshold [arg2] at Rank [arg3] Sub Rank [arg4]
Bank [arg5] Row [arg6] on Device [arg7]. [arg8]
Warning
FQXSFMA0030K Intel Optane DCPMM [arg1] Percentage Remaining is less than
[arg2]% and still functioning.
Warning
FQXSFMA0031K Intel Optane DCPMM [arg1] has reached 1% remaining spares block
and still functioning.
Warning
Chapter 4. UEFI events 155

Related product manuals