The power supply experiences an internal fault caused overcurrent condition
Severity: Critical
User Action:
1. Check power supply LEDs
If AC LED is not lit, check power cord and input voltage.
If DC LED is not lit, remove and reinstall power supply.
If error LED is lit, replace the power supply.
2. If fault recurs, please call service.
086F01AD: PS2_INTRL_OC_ERR: Power Supply, Power Supply Failure detected was asserted.
The power supply experiences an internal fault caused overcurrent condition
Severity: Critical
User Action:
1. Check power supply LEDs
If AC LED is not lit, check power cord and input voltage.
If DC LED is not lit, remove and reinstall power supply.
If error LED is lit, replace the power supply.
2. If fault recurs, please call service.
086F01AE: PS1_INTRMTNT_ERR: Power Supply, Power Supply Failure detected was asserted.
The power supply experiences an internal fault/non-overcurrent condition
Severity: Critical
User Action:
1. Check power supply LEDs
If AC LED is not lit, check power cord and input voltage.
If DC LED is not lit, remove and reinstall power supply.
If error LED is lit, replace the power supply.
2. If fault recurs, please call service.
086F01AF: PS2_INTRMTNT_ERR: Power Supply, Power Supply Failure detected was asserted.
The power supply experiences an internal fault/non-overcurrent condition
Severity: Critical
User Action:
1. Check power supply LEDs
If AC LED is not lit, check power cord and input voltage.
If DC LED is not lit, remove and reinstall power supply.
If error LED is lit, replace the power supply.
2. If fault recurs, please call service.
086F03E0: PS1: Power Supply, Power Supply input lost (AC/DC) was asserted.
The line cord input of indicated PSU is lost
Severity: Critical
User Action:
Information only; no action is required.
086F03E1: PS2: Power Supply, Power Supply input lost (AC/DC) was asserted.
The line cord input of indicated PSU is lost