User Action:
Information only; no action is required.
21080140: NODE1_PRESENT: Slot Or Connector, Device Inserted / Device Present was asserted.
The compute node is installed in the indicated slot.
Severity: Informational
User Action:
Information only; no action is required.
21080141: NODE2_PRESENT: Slot Or Connector, Device Inserted / Device Present was asserted.
The compute node is installed in the indicated slot.
Severity: Informational
User Action:
Information only; no action is required.
21080142: NODE3_PRESENT: Slot Or Connector, Device Inserted / Device Present was asserted.
The compute node is installed in the indicated slot.
Severity: Informational
User Action:
Information only; no action is required.
21080143: NODE4_PRESENT: Slot Or Connector, Device Inserted / Device Present was asserted.
The compute node is installed in the indicated slot.
Severity: Informational
User Action:
Information only; no action is required.
216F0058: NODE1_CAP_LOW: Slot Or Connector, Fault Status asserted was asserted.
The restored power cap value is invalid since it is lower than current power cap boundary
Severity: Critical
User Action:
Re-configure the power cap value of the compute node from web GUI or IPMI command
216F0059: NODE2_CAP_LOW: Slot Or Connector, Fault Status asserted was asserted.
The restored power cap value is invalid since it is lower than current power cap boundary
Severity: Critical
User Action:
Re-configure the power cap value of the compute node from web GUI or IPMI command
216F005A: NODE3_CAP_LOW: Slot Or Connector, Fault Status asserted was asserted.
The restored power cap value is invalid since it is lower than current power cap boundary
Severity: Critical
User Action:
Re-configure the power cap value of the compute node from web GUI or IPMI command
216F005B: NODE4_CAP_LOW: Slot Or Connector, Fault Status asserted was asserted.
32
ThinkSystem D2 Enclosure, Modular Enclosure, Modular Enclosure for 6U Configuration and ThinkSystem SD530 Compute Node
Messages and Codes Reference