The restored power cap value is invalid since it is lower than current power cap boundary
Severity: Critical
User Action:
Re-configure the power cap value of the compute node from web GUI or IPMI command
216F005C: NODE1_CAP_FAIL: Slot Or Connector, Fault Status asserted was asserted.
Failed to set power cap to compute node
Severity: Critical
User Action:
1. Re-configure the node power cap value
2. If the error recurs, reseat the node
3. If the error recurs, replace the node
216F005D: NODE2_CAP_FAIL: Slot Or Connector, Fault Status asserted was asserted.
Failed to set power cap to compute node
Severity: Critical
User Action:
1. Re-configure the node power cap value
2. If the error recurs, reseat the node
3. If the error recurs, replace the node
216F005E: NODE3_CAP_FAIL: Slot Or Connector, Fault Status asserted was asserted.
Failed to set power cap to compute node
Severity: Critical
User Action:
1. Re-configure the node power cap value
2. If the error recurs, reseat the node
3. If the error recurs, replace the node
216F005F: NODE4_CAP_FAIL: Slot Or Connector, Fault Status asserted was asserted.
Failed to set power cap to compute node
Severity: Critical
User Action:
1. Re-configure the node power cap value
2. If the error recurs, reseat the node
3. If the error recurs, replace the node
216F0060: NODE1_XCC_FAULT: Slot Or Connector, Fault Status asserted was asserted.
The BMC fail to start the initialisation in 2 minutes since the compute node inserted.
Severity: Critical
User Action:
1. Reset XCC
2. If the error recurs, reseat the node
Chapter 2. SMM2 events 33