FQXSPSD0007I: Rebuild in progress for Array in system [ComputerSystemElementName].
This message is for the use case when an implementation has detected that an Array Rebuild is in
Progress.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0178
User Action:
Information only; no action is required
FQXSPSD0007L: Array critical asserted on drive [arg1] in the enclosure/chassis (MTM-S/N: [arg2]).
This message is for the use case when an implementation has detected that an Array is Critical.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0174
User Action:
Replace the hard disk drive that is indicated by a lit status LED.
FQXSPSD0008I: Array rebuild in progress on drive [arg1] in the enclosure/chassis (MTM-S/N:
[arg2]).
This message is for the use case when an implementation has detected that an Array Rebuild is in
Progress.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0178
User Action:
Information only; no action is required
FQXSPSD0008L: Array failed on drive [arg1] in the enclosure/chassis (MTM-S/N: [arg2]).
This message is for the use case when an implementation has detected that an Array Failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0176
User Action:
Complete the following steps:
Chapter 2. XClarity Controller events 117