FQXSPUP0002I: A firmware or software change occurred on system
[ComputerSystemElementName].
This message is for the use case when an implementation has detected that the Firmware or Software
Changed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0438
User Action:
Information only; no action is required
FQXSPUP0007L: Invalid or Unsupported firmware or software was detected on system
[ComputerSystemElementName].
This message is for the use case when an implementation has detected an Invalid/Unsupported Firmware/
Software Version.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0446
User Action:
Reflash or update XCC firmware
FQXSPUP4000I: Please ensure that the Management Controller [arg1] is flashed with the correct
firmware. The Management Controller is unable to match its firmware to the server.
This message is for the use case where a Management Controller firmware version does not match the
server.
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0031
User Action:
Complete the following steps until the problem is solved:
1. Update the BMC firmware.
2. NOTE: Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.
FQXSPUP4001I: Flash of [arg1] from [arg2] succeeded for user [arg3] .