2.  If the problem persists, collect Service Data logs and contact Lenovo Support.
•  FQXSFPU4077G: Platform secure boot fuse is disabled but CPU 2 fused. 
Severity: Warning
User Action:
Complete the following steps:  
1.  If a CPU has been replaced with a new one, roll back the original CPU and reboot the system.
2.  If the problem persists, collect Service Data logs and contact Lenovo Support.
•  FQXSFPU4078G: Platform secure boot fuse is disabled but CPU 1,2 fused. 
Severity: Warning
User Action:
Complete the following steps:  
1.  If a CPU has been replaced with a new one, roll back the original CPU and reboot the system.
2.  If the problem persists, collect Service Data logs and contact Lenovo Support.
•  FQXSFPU4080I: Host Power-On password has been changed. 
Severity: Info
User Action:
Information only; no action is required. 
•  FQXSFPU4081I: Host Power-On password has been cleared. 
Severity: Info
User Action:
Information only; no action is required. 
•  FQXSFPU4082I: Host Admin password has been changed. 
Severity: Info
User Action:
Information only; no action is required. 
•  FQXSFPU4083I: Host Admin password has been cleared. 
Severity: Info
User Action:
Information only; no action is required. 
•  FQXSFPU4084I: Host boot order has been changed. 
Severity: Info
User Action:
Information only; no action is required. 
•  FQXSFPU4085I: Host WOL boot order has been changed. 
Severity: Info
User Action:
Information only; no action is required. 
Chapter 3. UEFI events 191