Information only; no action is required.
•  FQXPMUP0102I: Start to update window driver 
Severity: Info
User Action:
Information only; no action is required.
•  FQXPMUP0103I: Start to update linux driver 
Severity: Info
User Action:
Information only; no action is required.
•  FQXPMUP0104I: Start to update UEFI 
Severity: Info
User Action:
Information only; no action is required.
•  FQXPMUP0105I: Start to update BMC 
Severity: Info
User Action:
Information only; no action is required.
•  FQXPMUP0106I: Successfully updated the firmware 
Severity: Info
User Action:
Information only; no action is required.
•  FQXPMUP0201M: BMC communication failed: EMMC2USB mount failure. Failed to update the 
firmware 
Severity: Error
User Action:
1.  Restart BMC via supported method and BMC setting via uEFI setup or "Restart Management 
Controller" in BMC web UI. Then, reboot the system.
2.  If the problem persists, reflash the BMC firmware.
3.  If the problem persists, perform AC reset or virtual reseat.  
Note:  When performing AC reset, after powering off AC, wait several seconds before powering on 
AC. After AC power is restored, power on the host system.
4.  If the problem persists, try a different Lenovo tool to perform the update (eg. XClarity Administrator, 
XClarity Controller, or XClarity Essential OneCLI).
5.  If the problem persists, contact technical support.
•  FQXPMUP0202M: Transfer the update package error. Failed to update the firmware 
Severity: Error
User Action: