35
E
55
0-255 Mapping the function output D:
Function like CV54, effect on function output D
F2, Bit 2
set
59
Mapping the shunting speed: Determines which function is used
to enable the shunting speed automatically. If the shunting speed
is enabled, it is automatically switched over to speed-dependent
delay.
F3, Bit 3
set
60
Mapping the disabling of the delay:
Determines which function is used to disable the delay.
F4, Bit 4
set
61
1-255 Braking distance. If the value is 0, the speed-independent braking
distance is disabled.
100
62
0-99
Indicator – CV for the tens and units
0
63
0-99
Indicator – CV for the hundreds
0
64
0-255 Transport – CV for values. Please find further information on the
function of CVs 62 – 64 in the Section "Settings (programming) of
the S.U.S.I. module"
0
9 The S.U.S.I. interface
In cooperation with the company DIETZ, the concept of a sound and function interface for
locomotive decoders was devised in 2002. The purpose of the interface is to facilitate particularly
easy connection of the sound and other function modules to a locomotive decoder.
The S.U.S.I. module receives information on the running notch, the status of the functions etc. via
the interface and reacts accordingly, for example the sound of a bell is played or the locomotive
sound changes.