1.
General information
Caution:
The modules are fitted with
C-MOS and MOS components which are
sensitive against electrostatic
influences
Please note the following information, when the controller is
handled and checked;
otherwise these circuits may'be destroyed.
- Make sure that there is a potential compensation (charge
accumulation between controller, tools, measuring instruments,
and personnel before servicing.
- The modules must be touched at the edges, never'at the
components and their connections.
- Caution:
Controller is carriying mains potential up to 20s after
switching-off
- The phase current should be measured with a moving iron
instrument and the voltage with a moving coil instrument.
2.
Technical data
Output voltage 'phaseiv 3
X
0 "'Umains
Rated output current IN/A 3.4 4.0 7.0 9.5
Max. unit current I max/A 5.4 6.4 11.2 15.0
Power loss qp 50 70 90 150
fd=SoHZ, I=IN
Output frequency &/HZ 0 . . . 110
Master voltage ULN/' 0 . . . 10
Master current 'LNlmA 0 ,. 20 or 4 . . . 20
Ambient temperature
T,/OC
0 . . . 45
Dimensions HxBxD mm 155 x 202 x 230
Weight kg 2.2 2.9 4.0 4 . 0
lanze