EasyManua.ls Logo

Lenze E82MV222_4B - User Manual

Lenze E82MV222_4B
270 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
L
Operating Instructions
EDB82MV752
.5eI
Global Drive
8200 motec frequency inverter
0.25 kW ... 7.5 kW
Ä.5eIä

Table of Contents

Questions and Answers

  • J
    Jeffrey CastroSep 8, 2025
    What to do if Lenze DC Drives motor does not rotate because wrong parameter set is active?
    • J
      Justin FlowersSep 8, 2025
      If the Lenze DC Drives motor does not rotate and the wrong parameter set is active, change to the correct parameter set via terminal.
  • K
    kirbyrickySep 10, 2025
    What to do if Lenze DC Drives motor does not rotate because no motor parameter identification executed?
    • M
      martinezwilliamSep 10, 2025
      If the Lenze DC Drives motor does not rotate and the operating mode C0014 = '4' or '5', but no motor parameter identification has been executed, perform motor parameter identification (C0148).
  • H
    henry28Sep 12, 2025
    What to do if Lenze DC Drives motor does not rotate because of conflicting functions assigned to the same signal source?
    • A
      Anthony LynchSep 12, 2025
      If the Lenze DC Drives motor does not rotate and several mutually exclusive functions are assigned to the same signal source under C0410, correct the configuration in C0410.
  • E
    Ernest BallSep 13, 2025
    What to do if Lenze DC Drives motor does not rotate because of missing jumper?
    • W
      wesleytaylorSep 13, 2025
      If the Lenze DC Drives motor does not rotate and you are using the internal voltage source X3/20 for function modules Standard I/O, INTERBUS, PROFIBUS-DP, or LECOM-B (RS485), ensure that the jumper between X3/7 and X3/39 is present. If it's missing, jumper the terminals.
  • K
    Katherine MillerSep 15, 2025
    What to do if Lenze DC Drives motor does not rotate smoothly because motor underexcited or overexcited?
    • D
      Donald ByrdSep 15, 2025
      If the Lenze DC Drives motor does not rotate smoothly, and the motor is either underexcited or overexcited, check the parameter settings (C0015, C0016, C0014).
  • J
    Joseph WilliamsSep 18, 2025
    What to do if Lenze DC Drives motor does not rotate smoothly because of incorrect parameters?
    • N
      Nancy HoganSep 18, 2025
      If the Lenze DC Drives motor does not rotate smoothly, and parameters C0084, C0087, C0088, C0089, C0090, C0091, and/or C0092 are not adapted to the motor data, perform manual adaptation or identification of motor parameters (C0148).

Summary

Safety information

General safety and application instructions for Lenze controllers

Covers general safety, direct/indirect contact risks, qualified personnel, application as directed, and EMC directive compliance.

Residual hazards

Outlines specific residual hazards related to electrical voltage, heatsink temperature, device protection, and overspeed.

Technical data

Installation

Electrical installation

Details important notes on electrical installation, protection of persons, motor protection, mains types, and earth-leakage circuit breakers.

Commissioning

Before you start

Lists checks for mains voltage connection and important drive parameter settings before enabling the controller.

Before switching on

Details special commissioning procedures for long-time storage, including capacitor anodization.

Changing and saving parameters

Provides a step-by-step guide on how to change and save parameters using the keypad.

Commissioning - V;f characteristic control

Details the process for commissioning with V/f characteristic control, including without function module and with standard I/O.

Commissioning - vector control

Explains the process for commissioning with vector control, including parameter identification and configuration.

Parameter setting

General information

Explains parameterization, codes, and methods for setting parameters via keypad, PC, or bus system.

Parameter setting via keypad or PC

Details how to set parameters using the keypad, including installation, displays, functions, and menu structure.

Function library

Select control mode, optimise operating behaviour

Guides selection of operating modes like V/f control and vector control for optimal performance.

Behaviour in the event of mains switching, mains failure or controller inhibit

Describes controller behavior during mains interruptions, failures, or inhibit signals, including start conditions and deceleration.

Motor data entry;automatic detection

Explains how to enter or automatically detect motor data, crucial for vector control and sensorless torque control.

Troubleshooting and fault elimination

Maloperation of the drive

Explains controller responses to different error types (TRIP, message, warning) and common drive maloperations.

Fault messages on the keypad or in the parameter setting program Global Drive Control

Lists fault messages, their causes, and remedies for troubleshooting.

Automation

Braking operation

Application examples

Lenze E82MV222_4B Specifications