Mechanical installation
MA82ZBU 1.0
-2-
The switch/potentiometer unit can be mounted to the heatsink of a motec or a wall.
Mounting to the heatsink of a motec
0
4. Mount the mounting plate with 2
screwsM4x20and2springsteel
sheets
0
to the heat sink.
5. Wire the switch/potentiometer unit
-tothestandard-I/O
&
3
- to the application-I/O
&
4
6. Assemble the motec
&
Mounting Instructions for motec
7. Mount the switch/potentiometer unit
with4screwsM4x30
1
to the
mounting plate.
Wall mounting
1. Mount the mounting plate to the wall
using appropriate screws
2. Mount the switch/potentiometer unit
with4screwsM4x30tothe
mounting plate.
3. Wire the switch/potentiometer unit
-totheStandard-I/O
&
3
- to the Application-I/O
&
4
4. Assemble the motec
&
Mounting Instructions for motec