EasyManuals Logo

Lenze EVS9327EP User Manual

Lenze EVS9327EP
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #116 background imageLoading...
Page #116 background image
Function library
Positioning control
3.4.13 Program sets (PS)
3−88
l
EDSVS9332P−EXT DE 2.0
3.4.13.11 Prg. fct. "Branch 1"
Purpose
Branching during program processing depending on the digital input signals (PFI).
Branching because of conditional query of two variables (<, >, = <=, >=):
1. Comparison of two variables with function block CMPPH" (7−109)
2. Connect the CMPPH output to the desired POS−PFI.
9300pos023
Fig. 3−37 Diagram − Branches 1 and 2
Function
l Selection of any PFI under C1325/x.
l Selection of the signal level under C1326/x.
l Selection of the PS to be branched to PS under C1327/x (if the PFI has the level selected).
l 32 PFO are available (see POS−PFO).
l GDC input: Programming" dialog
l Default setting: not active
3.4.13.12 Prg. fct. Branch 2"
Purpose
See branch 1
Function
l Selection of any PFI under C1334/x.
l Selection of the signal level under C1335/x.
l Selection of the PS to be branched to PS under C1336/x (if the PFI has the level selected).
l 32 PFO are available (see POS−PFO).
l GDC input: Programming" dialog
l Default setting: not active