Function library
Function blocks
3.5.29 Digital frequency ramp function generator (DFRFG)
3−174
l
EDSVS9332P−EXT DE 2.0
3.5.29.4 RESET
DFRFG−RESET = HIGH:
l Resets setpoint phases which are internally added.
l Activates the profile generator.
l HIGH−LOW edge at DFRFG−RESET: Detecting the setpoint phase.
3.5.29.5 Detect phase difference
Monitoring the phase difference between input DFRFG−IN and output DFRFG−OUT.
l Set limit value of monitoring via C0754.
l Activates the monitoring: DFRFG−FAIL = HIGH
l Storing the signal until DFRFG−RESET = HIGH.
l The profile generator can accept a phase difference of up to ±2140000000 inc (= 32000
revolutions).