EasyManua.ls Logo

Lenze g500-S Series - Page 135

Lenze g500-S Series
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ICN-M40 connector assignment, hybrid
For One Cable Technology (OCT) with digital absolute value encoder
N
W
U V
1
2
+
-
DSL1
DSL2
B
A
PE
ICN M40 Hybrid for One Cable Technology (OCT) with digital absolute value encoder
Contact Name Meaning
U U Power phase U
V V Power phase V
W W Power phase W
A BD1 Holding brake +
B BD2 Holding brake -
PE PE PE
N Not assigned
DSL1 + VCC/data +
DSL2 - GND/data -
+ Not assigned
- Not assigned
1 + Oponal temperature monitoring: PTC +
2 - Oponal temperature monitoring: PTC -
Product extensions
Motor connecon
Connecon via ICN connector
135

Table of Contents

Other manuals for Lenze g500-S Series

Related product manuals