Mechanical installation
Preparation
Maximum permissible load at the motor adapter
4
25
Lenze ¯ MA 12.0018 ¯ 4.1
Furthermore the loading case of the force F
M
has to be taken into consideration:
Loading case k
loading
case
Static 1
Dynamic−pulsating 0.8
Dynamic−alternating 0.6
The position of the motor‘s centre of gravity, including all motor options, must be
calculated. If the distance of the centre of gravity L
Tab
is greater, the permissible force
must be reduced as follows.
U = k x F x k x F
Mzul Lasall MTab Lasall MTab
L
Tab
L
<
If forces act from several directions, e.g. in the case of a moving horizontal travelling
drive, the acting forces have to be added vectorially (e.g. vertical force due to weight plus
horizontal acceleration force).
F
Mperm
corresponds to the maximum value of the forces added vectorially!
L
F
M
If the permissible force F
Mperm
is exceeded, the motor has to be supported in a suitable,
distortion−free fashion!
Drive size
Distance L
Tab
of the motor
Gearbox type
B500−S130
G50BS113
g500−S220
G50BS122
g500−S400
G50BS140
g500−S660
G50BS166
[−] [mm] Maximum permissible force F
M
Tab
[N]
1A/2B 80 350 350 350 350
1B 80 550 600 800 800
xC 115 550 600 800 800
xD 115 550 800 1000 1300
xE 145 −−−−− 800 1000 1300
xF 145 −−−−− −−−−− −−−−− −−−−−
xG 190 −−−−− −−−−− −−−−− −−−−−
xH 250 −−−−− −−−−− −−−−− −−−−−
Drive size
Distance L
Tab
of the motor
Gearbox type
g500−S950
G50BS195
g500−S2100
G50BS221
g500−S3100
G50BS231
g500−S4500
G50BS245
[−] [mm] Maximum permissible force F
M
Tab
[N] Maximum permissible force F
M
Tab
[N]
1A/2B 80 −−−−− −−−−− −−−−− −−−−−
1B 80 800 800 800 −−−−−
xC 115 800 800 800 1500
xD 115 1500 1500 1500 1500
xE 145 1500 1500 1500 1500
xF 145 1500 1500 1500 1500
xG 190 1700 1700 1700 1700
xH 250 −−−−− 2600 3500 3500