EasyManua.ls Logo

Lenze g500-S2100 - Mounting the Fixed Cover

Lenze g500-S2100
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mechanical installation
Mounting of g500 short/servo adapters with clamping connection
Mounting the fixed cover
4
45
Lenze ¯ MA 12.0018 ¯ 4.1
4.3.12 Mounting the fixed cover
Note!
This cover can be ordered optionally and will then be loosely enclosed
with the shipment, or it is already mounted to the gearbox.
Gearbox size: g500−S130/G50BS113 ... g500−S950/G50BS195
With these sizes, the protective cap is clipped on.
X
X
Clip the protection cover into the bores, 6 x flange side, 4 x motor side.
Gearbox size: g500−S2100/G50BS221 ... g500−S19000/G50BS319
With these sizes, the cover is screwed together with the housing.
Gearbox size: g500−S2100/G50BS221 ... g500−S4500/G50BS245
With these sizes, additional reducing bushs are screwed into the gearbox housing
thread.
2
x
x
1
3
1 Protection cover 3 Reducing bush
2 Cheese head screw
1. Screw reducing bushes (3) into the flange so that they are flush using a
screwdriver.
2. Fasten the protective cap (1) over the reducing bushes (3) on the flange using
cheese head screws (2).

Table of Contents

Other manuals for Lenze g500-S2100

Related product manuals