Determine change intervals for lubricants
1.
Measure the lubricant temperature at the drain plug
2.
Add 10 C
3.
Determined the change interval from the diagram
Posion Of the drain plug 4Venlaon ^ 20
C
D
B
A
1000
100
60
10000
50000
70
80
90
110
A Oil sump temperature [°C] C Synthec oil: CLP HC/CLP PG
B Change interval in operang hours [h] D Mineral oil: CLP
Maintenance
Maintenance intervals
44