EasyManua.ls Logo

Lenze M Series - Page 15

Lenze M Series
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Identification
Product key
3 Product description
EN
E Design, shaft, concentricity/vibrational severity/direct gearbox attachment
Design
A Standard flange form A/FF with through hole, cyl. shaft without keyway
B Standard flange form A/FF with through hole, cyl. shaft with keyway
C Standard flange form C/FT with threaded holes, cyl. shaft without keyway
N Standard flange form C/FT with threaded holes, cyl. shaft with keyway (standard attachment)
F Same as version A except that flange is large V Same as version N except that flange is large
G Same as version B except that flange is large O Without flange and without keyway
U Same as version C except that flange is large P Without flange and with keyway
Shaft
11 Shaft 11x23 (MCS06) 24 Shaft 24x50 (MCS14; MCA14, 17)
14 Shaft 14x30 (MCS09; MCA 10) 28 Shaft 28x60 (MCS19; MCA19)
19 Shaft 19x40 (MCS12; MCA13) 38 Shaft 38x80 (MCA21)
Concentricity/vibrational severity/direct gearbox attachment
N or R Concentricity/vibrational severity
Z0X Direct gearbox attachment: Motor without pinion for mounting on open gearbox with pinion; flange for direct gearbox attachment without intermediate cover, with
tapered hollow shaft
Y0X Direct gearbox attachment: Motor without pinion for mounting on open gearbox with pinion; flange for direct gearbox attachment with intermediate cover, with
tapered hollow shaft
© Electrical connection, enclosure, cooling, load flywheel
Electrical connection
ST Separate circular connectors for power/brake, encoder/thermal detector, fan
SO Shared rectangular connector for power, encoder...
KK Separate terminal boxes for power/brake, encoder/thermal detector/fan
KG Separate terminal boxes for power/brake, blower circular connectors for encoder, thermal detector
KS Terminal box for power+brake; circular connector for encoder and thermal detector; circular connector for blower
SK Circular connector for power+brake; circular connector for encoder+thermal detector; terminal box for fan
Enclosure
2 IP23 6 IP65 with shaft sealing ring
5 IP54 without shaft sealing ring (except for direct mounting on gearbox)
A IP64 (A-flange, without shaft sealing ring) / IP65
B IP54 with shaft sealing ring (A-bearing, oil-tight)
C IP54 with shaft sealing ring, double lip (A bearing dust-tight)
D IP65 with double-lip shaft sealing ring
Cooling
S00 Self cooling/without fan F10 Blower 230V; AC; 1N
F1F Blower 230V; AC; 1N; filter F30 Blower 400V; AC; 3N
F3F Blower 400V; AC; 3N; filter F50 Blower 115V; AC; 1N
FWO Blower 480V; AC; 3N FWF Blower 480V; AC; 3N; filter
Load flywheel
N Without additional load flywheel | J With additional mass inertia
И Motor protection, electron. nameplate, color/specification, approval
Temperature protection
B NC thermal contact R KTY sensor
E KTY sensor; electronic nameplate
Electronic nameplate
0 Standard nameplate 2 Second nameplate supplied loose
1 Standard nameplate + electronic nameplate 3 Second nameplate supplied loose + electronic nameplate
Colour/specification
S Colour: black
U
Specification - UL design and CSA design, approval cWus
R
Specification - UL design, approval W
Ш Miscellaneous
16