EasyManua.ls Logo

Lenze MCS 06C60 - Terminal Box Encoder;Sensor Connections; Encoder and Temperature Connections

Lenze MCS 06C60
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Terminal box, SinCos absolute value encoder with Hiperface
Contact Name Meaning
B1 + UB Supply +
B2 GND Mass
B3 A Track A / + COS
B4 Track A inverse /-COS
B5 B Track B / +SIN
B6 Track B inverse/-SIN
B7 Z Zero track / + RS485
B8 Zero track inverse /-RS485
B10 Incremental encoder shield
Terminal box, SinCos absolute value encoder with EnDat
Contact Name Meaning
B1 + UB Supply +
B2 GND Mass
B3 A Track A / + COS
B4 A- Track A inverse /-COS
B5 B Track B / +SIN
B6 B- Track B inverse/-SIN
B7 Daten EnDat interface data
B8 Daten- Data inverse EnDat interface
B20 Takt EnDat interface cycle
B21 Takt- Inverse EnDat interface cycle
B22 Up Sensor Up Sensor
B23 0 V Sensor 0 V sensor
B24 Schirm Encoder housing shield
B25 Not assigned
Terminal box, temperature monitoring
Contact Name Meaning
R1 + Temperature sensor +
R2 - Temperature sensor -
Electrical installaon
Motor connecon
Connecon via terminal box
24