One Cable Technology (OCT)
Connecon of power, brake, feedback and temperature monitoring
ICN-M23 connector assignment, hybrid
For One Cable Technology (OCT) with digital absolute value encoder
1
2
3
4
U
A
B
W
D
C
V
+
ICN M23 Hybrid for One Cable Technology (OCT) with digital absolute value encoder
Contact Name Meaning
U U Power phase U
V V Power phase V
W W Power phase W
PE PE PE
A BD1 Holding brake +
B BD2 Holding brake -
C + Oponal temperature monitoring: PTC +
D - Oponal temperature monitoring: PTC -
1 Not assigned
2 + VCC/data +
3 - GND/data -
4 Not assigned
Electrical installaon
Motor connecon
Connecon via ICN connector