Loading...
Assembly of ICN connectors
NOTICE
Live cables!
Possible destrucon of the connector.
Never remove connector when voltage is being applied!
Disable inverter before removing the connector!
NOTICE
Loss of the protecon class due to incorrect mounng!
Malfuncons may occur.
ICN connector with screwed connecon: Do not remove O-ring
ICN connector with bayonet lock: remove O-ring and dispose of it.
1. When connecng the connector to the motor connector, make sure that the aids to
orientaon (pos. 1) are facing each other.
2. Tighten the box nut of the connector!
Motors with addional PE conductor connecon
As an addional protecve measure, a second PE conductor can be connected at the motor
housing if required:
Use PE-labelled bore hole at the motor housing
Remove coang for contact surface in the area of the bore hole
Ensure a good electrical conducvity of the contact
Establish a permanently safe electrical connecon
Electrical installaon
Motor connecon
Connecon via ICN connector
31