DMX Channels(slider) Value Function
Channel 1
Use as Speed control **
0 - 199
200 - 249
250 - 255
Speed (Quick - Slow)
Auto Run Mode
Sound Active Mode
Channel 2 - 8
Hint (Channels
2,3,4,5,6,7,8 means each
lighting lens)
0 - 31
32 - 127
139 - 146
147 - 154
155 - 162
163 - 170
171 - 178
179 - 186
187 - 194
195 - 202
203 - 210
211 - 218
219 - 226
227 - 234
235 - 242
243 - 250
251 - 255
All LED’s Off
Various Auto Patterns **
Red LED
Green LED
Red & Green LED
Blue LED
Blue & Red LED
Green & Blue LED
Blue, Red & Green LED
White LED
Red & White LED
Green & White LED
Red, Green & White LED
Blue & White LED
Red, White & Blue LED
Green, Blue & White LED
All LED’s On
Channel 9 0 - 255 All LED’s (as above ch 2-8)
DMX Controller Channel Modes
Lex Lighting Safety Instructions
1. Please keep this User Manual for future reference and be sure to pass this manual on to
anyone using the xture.
2. Always make sure that you are connecting to the proper voltage as stated on the decal or rear
panel of the xture.
3. This product is intended for indoor use only! To prevent risk of re or shock, do not expose
xture to rain or moisture.
4. Make sure there are no ammable materials close to the unit while operating.
5. The unit must be installed in a location with adequate ventilation, atleast 20inches (50 cm)
from adjacent surfaces. Be sure that no ventilation slots are blocked.
6. Always disconnect from power source before servicing or replacing fuse and be sure to
replace with same fuse rating.
7. Secure xture to fastening device using a safety chain.
8. Maximum ambient temperature (Ta) is 104° F (40° C). Do not operate xture at temperatures
higher than this.
9. In the event of a serious operating problem, stop using the unit immediately. Never try to
repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or
malfunction and will void your warranty. Please contact the nearest authorized technical
assistance center.
10. Never connect the device to a dimmer pack.
11. Make sure the power cord is never crimped or damaged.
12. Never disconnect the power cord by pulling or tugging on the cord.
13. Never carry the xture directly from the cord. Always use the hanging/mounting bracket.
14. Avoid direct eye exposure to the light source while it is on.
Question and Answer IconNeed help?

Do you have a question about the LEX Lighting Lex 7 Star and is the answer not in the manual?

LEX Lighting Lex 7 Star Specifications

General IconGeneral
Light SourceLED
LED Quantity7
Frequency50/60Hz
MaterialAluminum
IP RatingIP20

Summary

DMX Controller Channel Modes

Channel 1 DMX Control

Details DMX channel modes for Channel 1, including speed and auto modes.

Channels 2-8 DMX Control

Explains DMX modes for Channels 2-8, covering various LED color and pattern combinations.

Channel 9 DMX Control

Outlines DMX control for Channel 9, which governs all LEDs based on previous channel settings.

Lex Lighting Safety Instructions

Operational Safety Guidelines

Addresses safe voltage, indoor use, proximity of flammable materials, ventilation, and temperature limits.

Maintenance and Handling Safety

Covers power disconnection, fuse replacement, securing fixtures, cord handling, and avoiding direct eye exposure.

Auto Play Mode

Setting Auto Play Mode

Instructions to enable Auto Play mode by setting Dip Switch 8 to the ON position.

Sound Active Mode

Enabling Sound Active Mode

Details enabling Sound Active mode by setting Dip Switch 7 to ON and adjusting sensitivity.

Master/Slave Modes

Master Unit Configuration

Shows dip switch configuration for setting up the master unit in a linked lightshow.

Slave Unit Configuration

Explains dip switch settings for slave units to copy master settings.

DMX Mode

Setting DMX Mode

Instructions for setting the fixture to DMX mode by turning all dip switches OFF.

Assigning DMX Address

Details how to set a DMX address using dip switches 1-9 for controller communication.