Weight | 3.5 kg |
---|---|
Supply voltage | 24 V DC |
Ultimate Pressure | 0.5 mbar |
Power Supply | 24 VDC |
Operating Temperature | 0 to 50 °C |
Storage Temperature | -20 to 70 °C |
Measurement Range | 1E-9 mbar to 1000 mbar |
General information about the COMBIVAC CM 31, its readiness for use and importance of instructions.
Presents the technical specifications of the COMBIVAC CM 31, covering measurement ranges, units, sensors, and interface details.
Detailed explanation of measurement principles (THERMOVAC, PENNINGVAC) and interfaces.
Lists supplied equipment and available accessories for the COMBIVAC CM 31.
Guides the user through the initial start-up process, including power connection and self-test.
Explains how to connect the instrument to AC power, set line voltage, and replace fuses.
Explains the front panel controls, displays (bar graph, digital), and their functions.
Details the rear panel connections for AC power, gauges, and terminals.
Provides instructions for installation, including rack, panel, and table-top mounting.
Explains how to check TM and PM measurement channels using test gauges.
Describes the procedure for aligning THERMOVAC gauge heads to maintain accuracy.
Simple instructions for switching off the instrument by disconnecting power.
Explains various status messages like FAIL and FAULT, indicating sensor or system issues.
Provides tables detailing chart recorder output for TM and PM measurement channels.
Defines RS 232 C interface levels, modes (Printer, Remote Control), and basic operation.
Details fixed interface parameters like baud rate, data format, and end characters for communication.
Covers initial setup for remote control and printer operation, including cable links and parameters.
Explains measurement data output formats for remote control and printer modes.
Details commands for measurement data, parameter settings, and trigger adjustments.
Explains the format and meaning of interface error messages transmitted upon request.
Provides sample remote control commands for setting instrument parameters via RS 232.
Shows examples of cable wiring for connecting the instrument to an IBM PC.
Instructions for sending equipment for service, including the requirement for a contamination declaration.
Overview of navigating the first parameter level for adjusting thresholds, modes, and gas correction.
Details parameter settings in the second level for units, display resolution, cable length, and analogue output.