4. TotalAssemblylineprocess
4.1EDIDSerialNumberWrite
‐ThismodelDON’TneedtowritefullediddataforupdatetheSerialnumber.
JustwritetheS/Ndatabyusingadjustmentcommand.
Send Serial data
Send 24 byte
( EDID SN(4byte) + date (2byte) + Ascii SN(18byte) )
Read C/s of Serial data Read checksum data of 24 byte
4.2VerifyHDCPKey
CheckOSDwithagingonmodeorusingMasterSignalgeneratorwithHDCPOnandconnecttomonitorwithHDMI
IftheHDCPKeyisNG,thecolorofbackgroundwillbeRed,andifOK,itscolorwillbeWhiteasbelowpicture.
4.3SetAutomaticStandbytime
a.SetAutomaticStandbytimebyadjustmentjigequipment:Europe:4H,Others:OFF
Commandset:F70001(forEurope–set4h)
F70000(forothers–set0ff)
b.ChecktheAutomaticStandbytimeset tingvaluebyadjustmentjigequipment.
Pleasecheckthevalueof0xA60xEEaddress
Value:0x00‐OFF
0x04‐Set4H
4.4Factorycalibration
a. FactoryCalibration(2.2):Gamma,dE,ColorTemperature(6500k)
‐ReferenceModel:27MU67/27UD68/27UD88/27UD58/27UD88/32UD89/27UK850/27UK650/27UK600
‐Input:HDMI1/2,GrayPatternwithGammacorrectionusingcommandusing“AdjustmentCommand”
‐ThismodelmustbecalibratedGamma2.2
Gammacalibrationandverify
※whendoingAdjustment,Pleasemakecircumstanceasbelow.
- 18 -