THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FIRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFACTURES SPECIFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
COMP1/AV1/DVI_R_IN
COMP1/AV1/DVI_L_IN
SOC_RX
AV1_CVBS_DET
COMP1_DET
C3800
0.1uF
16V
COMP1_Y/AV1_CVBS
+3.3V_NORMAL
+3.5V_ST
COMP1_Pb
+3.3V_NORMAL
D3800
5.6V
AV_COMP_ESD
D3801
5.6V
AV_COMP_ESD
R3810
10K
DTV/MNT_V_OUT_SOC
P3800
12507WS-04L
UART_4PIN_STRAIGHT
1
2
3
4
5
COMP1_Pr
D3802
5.6V
AV_COMP_ESD
R3806
10K
D3803
5.6V
AV_COMP_ESD
SOC_TX
ZD3804
ADUC 5S 02 0R5L
OPT
R3800
75
1%
TU_DEBUG
JK3800
PPJ245-01
NON_Mold_AV
6A
[GN]C-SPRING
7A
[GN]E-LUG
4A
[GN]CONTACT
5B
[BL]C-SPRING
8C
[RD1]E-LUG-S
6C
[RD1]C-SPRING
4C
[RD1]CONTACT
5D
[WH]C-SPRING
4E
[RD2]CONTACT
6E
[RD2]C-SPRING
7E
[RD2]E-LUG
R3801
0
OPT
R3811
1K
R3812
1K
JK3800-*1
PPJ245N2-01
Mold_AV
6A
[GN/YL]O-SPRING
7A
[GN/YL]E-LUG
4A
[GN/YL]CONTACT
5B
[BL]O-SPRING
8C
[RD1]E-LUG-S
6C
[RD1]O-SPRING
4C
[RD1]CONTACT
5D
[WH]O-SPRING
4E
[RD2]CONTACT
6E
[RD2]O-SPRING
7E
[RD2]E-LUG
38
JACK_COMMON
2011.11.21
AV/COMPONENT REAR
DEBUG FOR INTERNAL AMOD.
UART FOR DEBUG
For TU_Debug
Disconnet R374