40
EXTERNAL CONTROL DEVICE SETUP
ENG
ENGLISH
Commandreferencelist
Communicationparameters
Baud rate: 9600 bps (UART)
Data length: 8 bits
Parity : None
Stop bit: 1 bit
Communication code: ASCII code
Use a crossed (reverse) cable.
* Note : During USB operations such as DivX or EMF, all commands except Power(ka) and Key(mc) are not
executed and treated as NG.
(Depending on model)
COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
01. Power k a 00 to 01 14. Bass k s 00 to 64
02. Aspect
Ratio
k c (See p.42) 15. Balance k t 00 to 64
03. Screen
Mute
k d (See p.42)
16. Colour
Temperature
x u 00 to 64
04. Volume
Mute
k e 00 to 01
17. Energy
Saving
j q 00 to 05
05. Volume
Control
k f 00 to 64
18. Auto Con-
figuration
j u 01
06. Contrast k g 00 to 64
19. Tune Com-
mand
m a
(See p.44)
07. Brightness k h 00 to 64
20. Programme
Add/Skip
m b 00 to 01
08. Colour k i 00 to 64 21. Key m c Key Code
09. Tint k j 00 to 64
22. Control
Back Light
m g 00 to 64
10. Sharpness k k (See p.43)
23. Input select
(Main)
x b (See p.45)
11. OSD Select k l 00 to 01
24. 3D x t (See p.45)
12. Remote
Control
Lock Mode
k m 00 to 01
25. Extended
3D
x v (See p.45)
13. Treble
k r 00 to 64
(Depending on model)