- 12 -
LGE Internal Use OnlyCopyright © 2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
(2) Manual adj. method
1) Set TV in Adj. mode using POWER ON.
2) Zero Calibrate the probe of Color Analyzer, then place it
on the center of LCD module within 10 cm of the surface.
3) Press ADJ key -> EZ adjust using adjustment remote
control. -> White-Balance then press the cursor to the
right key(G). (When Key(G) is pressed 216 Gray internal
pattern will be displayed)
4) One of R Gain / G Gain / B Gain should be fixed at 192,
and the rest will be lowered to meet the desired value.
5) Adj. is performed in COOL, MEDIUM, WARM 3 modes
of color temperature.
A If internal pattern is not available, use RF input. In EZ
Adj. menu 6.White Balance, you can select one of 2
Test-pattern: ON, OFF. Default is inner(ON). By
selecting OFF, you can adjust using RF signal in 216
Gray pattern.
A Adj. condition and cautionary items
1) Lighting condition in surrounding area
Surrounding lighting should be lower 10 lux. Try to
isolate adj. area into dark surrounding.
2) Probe location: Color Analyzer(CA-210) probe should
be within 10 cm and perpendicular of the module
surface. (80° ~ 100°)
3) Aging time
- After Aging Start, Keep the Power ON status during
5 Minutes.
- In case of LCD, Back-light on should be checked
using no signal or Full-white pattern.
5.3.6. Reference (White Balance Adj. coordinate
and temperature)
A Luminance : 216 Gray
A Standard color coordinate and temperature using CS-1000
(over 26 inch)
A Standard color coordinate and temperature using CA-
210(CH 9)
A Edge LED W/B Table in process of time(Only LGD module)
CA210 : CH 14, Test signal : Inner pattern(80 IRE)
5.4. HDCP(High-bandwidth Digital Contents
Protection) SETTING
- HDCP setting is not necessary in BCM model.
5.5. EYE-Q function check
Step 1) Turn on TV.
Step 2) Press EYE key of Adjustment remote control.
Step 3) Cover the Eye Q II sensor on the front of the using
your hand and wait for 6 seconds.
Step 4) Confirm that R/G/B value is lower than 10 of the “Raw
Data (Sensor data, Back light)”. If after 6 seconds,
R/G/B value is not lower than 10, replace Eye Q II
sensor.
Step 5) Remove your hand from the Eye Q II sensor and wait
for 6 seconds.
Step 6) Confirm that “ok” pop up. If change is not seen,
replace Eye Q II sensor.
5.6. Tool Option selection
- Method : Press ADJ key on the Adjustment remote control,
then select Tool option.
5.7. Ship-out mode check(In-stop)
After final inspection, press IN-STOP key of the Adjustment
remote control and check that the unit goes to Stand-by mode.
After final inspection, Always turn on the Mechanical S/W.
Mode Color Coordination Temp ∆UV
xy
COOL 0.269 0.273 13000 K 0.0000
MEDIUM 0.285 0.293 9300 K 0.0000
WARM 0.313 0.329 6500 K 0.0000
Mode Color Coordination Temp ∆UV
xy
COOL 0.269 ± 0.002 0.273 ± 0.002 13000 K 0.0000
MEDIUM 0.285 ± 0.002 0.293 ± 0.002 9300 K 0.0000
WARM 0.313 ± 0.002 0.329 ± 0.002 6500 K 0.0000
MODEL Tool 1 Tool 2 Tool 3 Tool 4 Tool 5
42LV375H 25953 12834 55332 22797 1059
GP2 Aging Time Cool Medium Warm
(Min.) X Y X Y X Y
269 273 285 293 313 329
1 0-2 279 288 295 308 319 338
2 3-5 278 286 294 306 318 336
3 6-9 277 285 293 305 317 335
4 10-15 276 283 292 303 316 333
5 20-35 274 280 290 300 314 330
6 36-49 272 277 288 297 312 327
7 50-79 271 275 287 295 311 325
8 80~149 270 274 286 294 310 324
9 Over~150 269 273 285 293 309 323