- 14 -
LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.
Only for training and service purposes
▪ If internal pattern is not available, use RF input. In EZ
Adj. menu 6.White Balance, you can select one of 2
Test-pattern: ON, OFF. Default is inner(ON). By selecting
OFF, you can adjust using RF signal in 206 Gray pattern.
* CASE Cool
First adjust the coordinate far away from the target
value(x, y).
1) x, y > target
i) Decrease the R, G.
2) x, y < target
i) First decrease the B gain,
ii) Decrease the one of the others.
3) x > target, y < target
i) First decrease B, so make y a little more than the
target.
ii) Adjust x value by decreasing the R.
4) x < target, y > target
i) First decrease B, so make x a little more than the
target.
ii) Adjust x value by decreasing the G.
How to adjust
1. If G gain is adjusted over 172 and R gain and B
gain less than 192 , Adjust is O.K.
2. If G gain is less than 172 , increase G gain by up to
172, and then increase R gain and B gain same
amount of increasing G gain.
3. If R gain or B gain is over 255 , Readjust G gain
less than 172, Conform to R gain is 255 or B gain is
255
* CASE Medium / Warm
First adjust the coordinate far away from the target
value(x, y).
1) x, y > target
i) Decrease the R, G.
2) x, y < target
i) First decrease the B gain,
ii) Decrease the one of the others.
3) x > target, y < target
i) First decrease B, so make y a little more than the
target.
ii) Adjust x value by decreasing the R
4) x < target, y > target
i) First decrease B, so make x a little more than the
target.
ii) Adjust x value by decreasing the G
▪ Adjustment condition and cautionary items
1) Lighting condition in surrounding area
Surrounding lighting should be lower 10 lux. Try to
isolate adj. area into dark surrounding.
2) Probe location
: Color Analyzer(CA-210) probe should be within 10 cm
and perpendicular of the module surface (80° ~ 100°)
5.2.6. Reference (White balance Adj. coordinate and
color temperature)
▪ Luminance : 204 Gray
▪ Standard color coordinate and temperature using CS-1000
(over 26 inch)
▪ Standard color coordinate and temperature using CA-210(CH 14)
5.2.7. LED White balance table
- EDGE LED module change color coordinate because of
aging time.
- Apply under the color coordinate table, for compensated
aging time.
* March to December & Global
Model : (normal line) LB567/LB58
Model : (aging chamber) LB567/LB58
Mode
Coordinate
Temp ∆uv
x y
Cool 0.271 0.270 13000K 0.0000
Medium 0.286 0.289 9300K -3.0000
Warm 0.313 0.329 6500K 0.0000
Mode
Coordinate
Temp ∆uv
x y
Cool 0.271 ± 0.002 0.270 ± 0.002 13000 K 0.0000
Medium 0.286 ± 0.002 0.289 ± 0.002 9300 K -3.0000
Warm 0.313 ± 0.002 0.329 ± 0.002 6500 K 0.0000
NC4.5
Aging
time
(Min)
Cool Medium Warm
x y x y x y
271 270 286 289 313 329
1 0-2 281 287 295 310 320 342
2 3-5 280 285 294 308 319 340
3 6-9 278 284 292 307 317 339
4 10-19 276 281 290 304 315 336
5 20-35 275 277 289 300 314 332
6 36-49 274 274 288 297 313 329
7 50-79 273 272 287 295 312 327
8 80-119 272 271 286 294 311 326
9 Over 120 271 270 285 293 310 325
NC4.5
Aging
time
(Min)
Cool Medium Warm
x y x y x y
271 270 285 293 313 329
1 0-5 280 285 294 308 319 340
2 6-10 276 280 290 303 315 335
3 11-20 272 275 286 298 311 330
4 21-30 269 272 283 295 308 327
5 31-40 267 268 281 291 306 323
6 41-50 266 265 280 288 305 320
7 51-80 265 263 279 286 304 318
8 81-119 264 261 278 284 303 316
9 Over 120 264 260 278 283 303 315