- 15 -
LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.
Only for training and service purposes
4.4.6. Reference (White Balance Adj. coordinate and
color temperature)
▪ Luminance: 204 Gray
▪ Standard color coordinate and temperature using CS-1000
(over 26 inch)
Mode
Coordinate
Temp △uv
X Y
Cool 0.269 0.273 13,000K 0.0000
Medium 0.285 0.293 9,300K 0.0000
Warm 0.313 0.329 6,500K +0.0030
▪ Standard color coordinate and temperature using CA-210(CH
18)
Mode
Coordinate
Temp △uv
X Y
Cool 0.269±0.002 0.273±0.002 13,000K 0.0000
Medium 0.285±0.002 0.293±0.002 9,300K 0.0000
Warm 0.313±0.002 0.329±0.002 6,500K 0.0000
(2) O/S Module(AUO, CMI, Sharp,IPS…)
Mode
Coordinate
Temp △uv
X Y
Cool 0.271±0.002 0.276±0.002 13,000K 0.0000
Medium 0.287±0.002 0.296±0.002 9,300K 0.0000
Warm 0.315±0.002 0.332±0.002 6,500K 0.0000
▪ Standard color coordinate and temperature using
CA-210(CH-18) – by aging time
GP4
Aging time
(Min)
Cool Medium Warm
X Y X Y X Y
269 273 285 293 313 329
1 0-2 283 293 299 313 320 339
2 3-5 282 291 298 311 319 337
3 6-9 281 290 297 310 318 336
4 10-19 279 289 295 309 316 335
5 20-35 277 284 293 304 314 330
6 36-49 274 279 290 299 311 325
7 50-79 271 277 287 297 308 323
8 80-149 270 274 286 294 307 320
9 Over 150 269 273 285 293 306 319
4.5. Option selection per country
4.5.1. Overview
(1) Press ADJ key on the Adj. R/C, and then select Country
Group Menu.
(2) Depending on destination, select KR or US, then on the
lower Country option, select US, CA, MX. Selection is done
using +, - KEY
4.6. Tool Option Inspection
▪ Method: Press Adj. key on the Adj. R/C, then select Tool option.
Model Tool 1 Tool 2 Tool 3 Tool 4 Tool 5 Tool 6 Tool 7
47G2-UG
32903 8258 30472 12332 18441 1322 5771
55G2-UG
32905 8258 30472 12332 18441 1322 5771
4.7. Local Dimming Inspection (Optional)
(1) Press ‘TILT” key of the Adj. R/C and check moving
patterns. The black bar patterns moves from top to bottom.
If a local dimming function does not work, a whole screen
shows full white
4.8. Ship-out mode check (In-stop)
▪ After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode.
▪ After final inspection, Always turn on the Mechanical S/W.
4.9. WIFI MAC ADDRESS CHECK
a. Using RS232
Command Set ACK
Transmission [A][l][][Set ID][][20][Cr] [O][K][x] or [N][G]
b. check the menu on in-start
Note that there are Wi-Fi MAC and MAC address.
Wi-Fi MAC is used for wireless network and MAC address is used
for wired network