ENGLISH
41
[Input Manager]
You can set the PC or DTV label for each external input.
[SIMPLINK Setup]
When the [SIMPLINK Setup] is set to [On], you can use the SIMPLINK provided by LG Signage.
[Device ID]: Set the ID of the device connected via CEC wiring. You can choose a value between [All] and [E].
[Standby]: Sets the scenarios for sending and receiving the OpStandBy (0x0c) command. Detailed scenarios are as
follows:
Transmission Reception
All O O
Send Only O X
Receive Only X O
[Crestron]
(Depending on model)
This function enables synchronization with applications provided by Crestron.
Server: This menu sets the server’s IP address for the network connection with the server (equipment provided by
Crestron).
Port (1024~65535): This menu sets the port for the network connection with the server. The default port number is
41794.
IP ID (3-254): This menu sets a unique ID for synchronizing with the application.
The connection status of the server type shall be indicated by pictures and phrases. (Disconnected, Connecting,
Connected)
Type: You can select the server type you want to connect to (Off, Control System, Virtual Control, Fusion)
CONNECT: If you press the button once, a set tries to connect to the server and the button phrase is changed into
DISCONNECT. In this case, the upper items are immutable. To disconnect and change upper items, pressing the button
again is needed.
Information for connecting with the server
- Type: Control System
- Server: Enter the IP information of the server
- Port: Enter the Port information for the server
- IP ID: A unique ID that distinguishes crestron equipment from server
- Type: Virtual Control
- Room ID: A unique ID that distinguishes room from server. If the IP ID is the same, but the Room ID is different,
the server recognizes it as a different crestron equipment.
- Server, Port, IP ID are the same as Control System’s.
- Type: Fusion
- Method: Connection direction can be selected. (Device to Fusion, Fusion to Device)
- Device to Fusion: How to connect from set to server
- URL: Server URL
- Port: Server Port
- Fusion to Device : How to connect from server to set

Table of Contents

Other manuals for LG 75XS4G-B.AWM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG 75XS4G-B.AWM and is the answer not in the manual?

LG 75XS4G-B.AWM Specifications

General IconGeneral
BrandLG
Model75XS4G-B.AWM
CategoryDigital Signage
LanguageEnglish

Related product manuals