LG
Multi Type Air Conditioner
SERVICE MANUAL
LG
CAUTION
website http://www.lgservice.com
• BEFORE SERVICING THE UNIT, READ THE SAFETY
PRECAUTIONS IN THIS MANUAL.
• ONLY FOR AUTHORIZED SERVICE PERSONNEL.
MODEL
Indoor Unit:
Outdoor Unit: A2UW146FA0
A2UW146FA1
A2UW146FA2
A2UW166FA0
A2UW166FA1
A2UW186FA0
A3UW186FA0
A3UW186FA1
A3UW246FA0
A4UW246FA0
A4UW306FA0
A4UW306FA1
A6UW406FA0
Room Type
Art Cool Deluxe Type
Duct Type 1 Way CST
AMNH096BTG0
AMNH126BTG0
AMNH186BTG0
AMNH096BPA0
AMNH126BPA0
AMNH186BHA0
AMNH246BHA0
AMNC246BHA0
AMNH306BGA0
AMNC306BGA0
AMNH366BGA0
AMNC366BGA0
AMNH09GB1A0
AMNH12GB1A0
AMNH18GB2A0
AMNH24GB2A0
AMNH076LQL0
AMNH096LQL0
AMNH096LRL0
AMNH126LRL0
AMNH186LTL0
AMNH246LTL0
AMNH07GD4L0
AMNH09GD4L0
AMNH12GD4L0
AMNH18GD5L0
AMNH24GD5L0
AMNH096AP*1
AMNH126AP*1
AMNH076DZ*0
AMNH096DU*0
AMNH126DU*0
AMNH186D3*0
AMNH246D3*0
AMNH07GDZ*0
AMNH09GDU*0
AMNH12GDU*0
AMNH18GD3*0
AMNH24GD3*0
AMNH07GDE*0
AMNH09GDE*0
AMNH12GDE*0
AMNH096TCC0
AMNC096TCC0
AMNH126TCC0
AMNC126TCC0
AMNH09GTCC0
AMNH12GTCC0
4 Way CST
AMNH096TEC0
AMNH126TEC0
AMNH186TEC0
AMNH246TFC0
AMNH306TFC0
AMNH366TDC0
AMNH306TFA0
AMNC306TFC0
AMNC366TDC0
AMNH09GTEF0
AMNH12GTEF0
AMNH18GTEF0
AMNH24GTHF0
CVT
AMNH096VEA0
AMNH126VEA0
AMNH186VBA0
AMNH246VBA0
Art Cool Type

Table of Contents

Other manuals for LG A4UW306FA1

Question and Answer IconNeed help?

Do you have a question about the LG A4UW306FA1 and is the answer not in the manual?

Summary

Model Number Nomenclature

Indoor Unit

Explains the structure and components of indoor unit model numbers.

Outdoor Unit

Explains the structure and components of outdoor unit model numbers.

Indoor Units

Details model number structures for various indoor unit types like Wall Mounted, Art Cool.

Outdoor Units

Details model number structures for Outdoor Units, including TPS Inverter Multi Series.

Safety Precautions

Installation

Safety guidelines for installing the unit, including grounding and circuit breakers.

Dimensions

Indoor Unit

Provides dimensions for Split Type and Art Cool Type indoor units.

Art Cool Deluxe Type

Details dimensions for SZ, SU, S3, and SE models of Art Cool Deluxe units.

Duct Type

Provides dimensions for BH/BG and BP, BT/BT1/B1/B2 chassis.

CVT Type

Shows dimensions for VE (8K/12K) and VB (18K/24K) models.

CST Type - TC,TC1 (9 K;12 K)

Provides detailed dimensions and connection points for CST Type TC, TC1 (9K/12K).

CST Type - TE(1) (9 K;12 K;18 K)

Details dimensions and mounting information for CST Type TE(1) units.

CST Type - TF (24 K;30 K)

Provides dimensions and mounting details for CST Type TF (24K/30K) units.

CST Type - TH (24 K)

Shows dimensions and mounting instructions for CST Type TH (24K) units.

CST Type - TD(36 K)

Details dimensions and mounting information for CST Type TD (36K) units.

Outdoor Unit

Provides dimensions for various outdoor unit models like UL, UE, UE1, UE2, UH.

Product Specifications

Indoor Unit

Lists detailed specifications for Wall Mounted and Art Cool Deluxe indoor units.

Indoor Unit Type

Details specifications for ART COOL Mirror and Wall Mounted indoor units.

Ceiling Cassette Type Indoor Unit

Covers specifications for Ceiling Cassette - 1way and 4way indoor units.

Ceiling Concealed Duct Indoor Unit

Provides specifications for Ceiling Concealed Duct units.

Outdoor Unit

Lists specifications for TPS Inverter Multi - Multi Piping Type outdoor units.

LG Branch Distributor

Details specifications for LG Branch Distributors PMBD3640, PMBD3630, etc.

Installation

Select the best location of indoor unit

Provides criteria for selecting the optimal location for indoor units.

Split Type Indoor Unit Installation

Step-by-step guide for mounting installation plates and drilling holes for room type units.

Art Cool Type Indoor Unit Installation

Explains how to open the front panel, remove covers, and connect the drain hose.

Duct Type Indoor Unit Installation

Explains installation methods (suspension/console bolts) and notes for duct type units.

CST Type Indoor Unit

Provides installation requirements for CST Type indoor units, including maintenance space.

CVT Type Indoor Unit Installation

Details installation guidelines for CVT Type indoor units, focusing on placement and air circulation.

Piping and Drainage of Indoor Unit

Instructions for cutting pipes and cables, and removing burrs.

Connection of indoor unit piping

Step-by-step guide for connecting piping and drain hoses for split type indoor units.

Connecting Pipings and the cable to Outdoor unit

Explains the necessity of using connectors for piping installation.

Maximum Length of Pipe and Extra Charge of Refrigerant Charge

Specifies maximum allowable piping lengths for TPS Inverter Multi systems.

Refrigerant charge

Explains how to calculate additional refrigerant charge based on pipe length and model.

Remote Controller Installation

Installation of the remote controller

Guidelines for selecting a suitable location for the remote controller installation.

Routing of the remote controller cord

Instructions on how to route the remote controller cord, avoiding interference and water.

WIRED REMOTE CONTROL INSTALLATION

Details the process of installing wired remote controls, including disassembling the box.

REMOTE CONTROL PREPARATION(OPTIONAL)

Instructions on how to insert batteries into the remote controller.

HOW TO MOUNT ONTO A WALL

Provides guidance on mounting the remote controller onto a wall.

Electric characteristics

Unit

Provides electrical characteristics (MCA, MOP, RLA, KW, FLA) for various indoor and outdoor units.

Checking the Drainage and Pipe forming

Split Type Indoor Unit

Steps to remove the grille and check the drainage for split type indoor units.

Art Cool Type Indoor Unit

Instructions to check the drain hose for Art Cool Type indoor units by pouring water.

Art Cool Deluxe Type Indoor Unit

Covers removing the front panel, checking drainage, and drain piping for Art Cool Deluxe units.

Convertible Type Indoor Unit

Instructions for removing the front panel, checking drainage, and proper drain piping for convertible units.

Duct Type Indoor Unit

Emphasizes unit declination for drainage and provides correct/incorrect piping dimensions.

CST Type Indoor Unit

Details drain piping requirements for CST Type units, including down-slope and insulation.

Drain test

Procedure to test the drain pump operation by feeding water and checking for leaks.

Test Running

SPLIT, ART cool, ART cool deluxe Type

Covers connecting, preparing the remote, and evaluating performance for specific unit types.

CVT Type

Details power supply connection, remote control preparation, and operation evaluation for CVT units.

Ceiling Cassette Type

Outlines precautions for test runs and checks to perform after installation is complete.

Operation

Function of control

Displays overview of operation indicators, sleep timer, timer, and defrost indicators.

Cooling Mode Operation

Explains compressor and fan operation logic based on intake air temperature.

Soft Dry Operation Mode

Describes operation logic for soft dry mode, including temperature adjustments and fan behavior.

Heating Mode Operation

Explains compressor and fan operation logic for heating mode based on intake air and pipe temperatures.

Fuzzy Operation

Describes how operation mode, compressor, fan, and 4-way valve are selected based on intake air temperature.

Airflow Speed Selection

Explains how to set airflow speed using the remote control.

On-Timer Operation

Describes the function of the on-timer, including LED indicators and operation continuity.

Jet Cool Mode Operation

Details the Jet Cool mode operation, including fan speed, temperature control, and vane reset.

Function of Indoor Unit

Explains operation controls, temperature sensing, fan speed, and special modes like PLASMA.

Art Cool Type Indoor Unit

Details operation controls, temperature sensing, fan speed, and special modes like PLASMA.

Art Cool Deluxe Type Remote Controller

Explains operation display, buttons, and modes for the Art Cool Deluxe Type remote controller.

Duct Type Remote Controller

Explains operation display, buttons, and modes for the Duct Type Remote Controller.

CST Type Remote Controller

Details operation display, buttons, and modes for the CST Type Remote Controller.

Convertible Type Remote Control

Explains operation controls, temperature sensing, fan speed, and special modes for convertible units.

Function of Outdoor Unit

Explains the operation logic of the outdoor unit components like compressor and fans.

Remote Control Operation

Details the functionality of each button on the remote controller.

Control Devices and Function

Simple Central Control

Explains the features of the simple central control system.

Term of Each part and Function

Details the functions of On/Off display LEDs, power LEDs, and control buttons.

PICTORIAL VIEW OF THE CONNECTION

Illustrates the physical connections between outdoor and indoor units for central control.

ONE SIMPLE CENTRAL CONTROL CONNECTION

Shows the wiring diagram for connecting multiple indoor units to the central control.

2 OR MORE SIMPLE CENTRAL CONTROL CONNECTION

Explains how to connect multiple simple central control units in master/slave configurations.

PI485 setting method(LG Aircon Network unit)

Details the setting method for PI485 modules for LG Aircon Network units.

Settings method of TPS Inverter Multi Type

Explains setting methods for TPS Inverter Multi type systems, including connection options.

Indoor Unit Address setting Method

Steps to set the indoor unit address using a wired or wireless remote controller.

Test run method

Provides critical cautions regarding installation locations to avoid issues.

LINK OF CONNECTING WIRE

Details how to connect wires between the controller, outdoor unit, and central control.

Deluxe Central Control

Provides a summary of the Deluxe Central Control system's capabilities and benefits.

Major Characteristics

Highlights major characteristics like individual operation, group management, and self-diagnosis.

System Configuration

Centralized control of indoor units, touch pad, GUI, and power failure compensation.

Disassembly of the parts (Indoor unit)

Split Type Indoor unit

Instructions for disconnecting power and removing the grille from split type indoor units.

To remove the Control Box.

Instructions for removing the control box and its screws.

To remove the Evaporator.

Instructions for removing the evaporator and its holder.

Art Cool Type Indoor Unit

Instructions for removing the grille and control box from Art Cool Type indoor units.

Art Cool Deluxe Type Indoor Unit(SZ,SU,S3)

Instructions for removing the grille and control box for SZ, SU, S3 chassis.

Art Cool Deluxe Type Indoor Unit(SE)

Instructions for removing the grille and control box for the SE chassis.

CVT Type - VB chassis

Instructions for removing the air filter, grille, and lower air guide for VB chassis.

VE chassis

Instructions for removing the grille and control box for VE chassis.

Remove air guide upper, crossflow fan and motor.

Steps for removing upper air-guide, fan motor, and associated parts.

Remove the drain pan assembly.

Steps for removing the drain pan assembly and its packing.

Schematic Diagram

Electronic Control Device

Schematic diagram of the electronic control device for split type indoor units.

Art Cool Type

Schematic diagram of the electronic control device for Art Cool Type indoor units.

Art Cool Deluxe Type

Schematic diagram of the electronic control device for Art Cool Deluxe Type (A/C MOTOR).

Duct Type

Schematic diagram of the electronic control device for Duct Type indoor units.

SLIM DUCT(B1,B2)

Schematic diagram of the electronic control device for Slim Duct (B1, B2) chassis.

Convertible Type

Schematic diagrams for AC part and DC part of Convertible Type units.

VB chassis

Schematic diagram of the electronic control device for VB chassis.

Outdoor Unit

Schematic diagram for Outdoor Unit models A2UW146FA0/1/2, A2UW166FA0/1, etc.

Wiring Diagram

Wiring diagrams for Room Type, Art Cool Type, Duct Type, and Art Cool Deluxe Type indoor units.

Components Locations

Shows component layout on the MAIN P.C.B ASM for Split Type indoor units.

Troubleshooting Guide

Refrigeration Cycle Diagram

Refrigerant flow diagrams for outdoor unit models A2UW146FA0/1/2, A2UW166FA0/1, etc.

Self-diagnosis Function

Lists error codes for indoor units, their descriptions, and indicator status.

Trouble analysis

Guides troubleshooting based on temperature difference and operating current.

Electronic Parts Troubleshooting Guide

Guides for diagnosing issues when the product does not operate at all.

Trouble 2

Steps to diagnose problems when the product does not operate with the remote controller.

Trouble 3

Guides for diagnosing problems when the compressor or outdoor fan does not operate.

Trouble 4

Steps to diagnose issues when the indoor fan does not operate.

Trouble 5

Guides for diagnosing problems when the louver does not operate.

Error Indicator (Outdoor)

Explains outdoor error indicators (LED01G, LED02G) and lists common outdoor errors.

Troubleshooting CH01, CH02, CH06

Detailed checks for indoor air sensor, inlet pipe sensor, and outlet pipe sensor issues.

Troubleshooting CH03

Steps to diagnose communication errors between wired remote and indoor unit.

Troubleshooting CH04

Guides for diagnosing drain pump and float switch problems.

Troubleshooting CH05, CH53

Steps to diagnose communication errors between indoor and outdoor units.

Troubleshooting CH21

Guides for diagnosing DC Peak errors, including wire connections and compressor resistance.

Troubleshooting CH22

Steps to diagnose C/T internal circuit errors, including power source and fan checks.

Troubleshooting CH23, CH28

Guides for diagnosing DC Link voltage errors (low and high).

Troubleshooting CH24, CH25

Steps to diagnose press switch and input voltage errors.

Troubleshooting CH26, CH27

Guides for diagnosing DC compressor position and PSC fault errors.

Troubleshooting CH32, CH33

Steps to diagnose D-pipe temperature errors for INV and Constant compressors.

Troubleshooting CH41, CH44, CH45, CH46, CH47, CH65

Guides for diagnosing various sensor errors (D-pipe, Air, Condenser, Suction, Heat Sink).

Troubleshooting CH51, CH60

Steps to diagnose over capacity and EEPROM check sum errors.

Troubleshooting CH61, CH62

Guides for diagnosing high condenser pipe and heat sink temperatures.

(3-way) Valve

3-way Valve (Liguid Side)

Illustrates and describes the shaft position and service port for the 3-way valve (liquid side).

3-way Valve (Gas Side)

Illustrates and describes the shaft position and service port for the 3-way valve (gas side).

Pumping down

Step-by-step procedure for pumping down the system before servicing.

Evacuation

Procedure for evacuating the system, including vacuum pump connection and monitoring.

Gas Charging

Step-by-step guide for charging the system with refrigerant after evacuation.

Exploded View & Replacement Parts List

Indoor Unit

Exploded view of the SQ/SR chassis indoor unit, showing all parts with location numbers.

Parts List (SQ, SR chassis)

Lists part numbers and descriptions for SQ/SR chassis indoor units.

ST chassis

Exploded view of the ST chassis indoor unit, showing all parts with location numbers.

Parts List (ST chassis)

Lists part numbers and descriptions for ST chassis indoor units.

S4, S5 chassis

Exploded view of the S4, S5 chassis indoor unit, showing all parts with location numbers.

Parts List (S4, S5 chassis)

Lists part numbers and descriptions for S4, S5 chassis indoor units.

SP1 chassis(Art cool type)

Exploded view of the SP1 chassis indoor unit (Art Cool Type), showing all parts with location numbers.

Parts List(Art cool Deluxe Type A;C Motor)

Lists part numbers for Art Cool Deluxe Type (A/C Motor) units.

Art Cool Deluxe Type(SU,SZ, S3 chassis - A;C Motor)

Exploded view showing parts for Art Cool Deluxe Type (SU,SZ,S3 chassis - A/C Motor).

Parts List(Art cool Deluxe Type BLDC)

Lists part numbers for Art Cool Deluxe Type (BLDC) units.

Art Cool Deluxe Type(SU,SZ, S3 chassis - BLDC)

Exploded view showing parts for Art Cool Deluxe Type (SU,SZ,S3 chassis - BLDC).

Convertible Type (VE chassis)

Exploded view of the Convertible Type (VE chassis) indoor unit, showing all parts.

Parts List(Convertible Type-VE chassis)

Lists part numbers for Convertible Type (VE chassis) models.

Convertible Type (VB chassis)

Exploded view of the Convertible Type (VB chassis) indoor unit.

Parts List(Convertible Type-VB chassis)

Lists part numbers for Convertible Type (VB chassis) models.

Duct Type - High Static

Exploded view of the Duct Type - High Static chassis indoor unit.

Parts List(Duct Type - High Static )

Lists part numbers for Duct Type - High Static chassis.

Duct Type - Low Static (BT, BT1 chassis)

Exploded view of the Duct Type - Low Static (BT, BT1 chassis) indoor unit.

Parts List (Duct Type - Low Static)

Lists part numbers for Duct Type - Low Static (BT, BT1) chassis.

Built in Duct type (BP chassis)

Exploded view of the Built in Duct type (BP chassis) indoor unit.

Parts List(Built in Duct Type-BP chassis)

Lists part numbers for Built in Duct Type (BP chassis).

Cassette Type - 1 way (TC1 chassis)

Exploded view of the Cassette Type - 1 way (TC1 chassis) indoor unit.

Parts List(Cassette Type - 1 way)

Lists part numbers for Cassette Type - 1 way (TC chassis).

Cassette Type - 1 way (TC chassis)

Exploded view of the Cassette Type - 1 way (TC chassis) indoor unit.

Parts List(Cassette Type - 1 way)

Lists part numbers for Cassette Type - 1 way (TC/TC1 chassis).

Cassette Type - 4 way[TE(1) chassis]

Exploded view of the Cassette Type - 4 way (TE(1) chassis) indoor unit.

Cassette Type - 4 way(TH chassis)

Exploded view of the Cassette Type - 4 way (TH chassis) indoor unit.

Parts List(Cassette Type - 4 way - TD 36 K)

Lists part numbers for Cassette Type - 4 way (TD 36K) models.

Parts List(Cassette Type - 4 way - TF 24 K, 30 K)

Lists part numbers for Cassette Type - 4 way (TF 24K, 30K) models.

Parts List(Cassette Type - 4 way - TH)

Lists part numbers for Cassette Type - 4 way (TH) models.

Outdoor Unit

Exploded view of Outdoor Unit models A2UW146FA2, A2UW166FA0, A2UW166FA1.

LG A4UW306FA1 Specifications

General IconGeneral
BrandLG
ModelA4UW306FA1
CategoryAir Conditioner
LanguageEnglish

Related product manuals