EasyManua.ls Logo

LG A4UH306FA0 - User Manual

LG A4UH306FA0
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
LG
Free Joint Multi Type
Air Conditioner
SERVICE MANUAL
LG
CAUTION
website http://www.lgservice.com
e-mail http://www.lgeservice.com/techsup.html
• BEFORE SERVICING THE UNIT, READ THE SAFETY
PRECAUTIONS IN THIS MANUAL.
• ONLY FOR AUTHORIZED SERVICE PERSONNEL.
MODEL Cooling Model Heating Model
• Outdoor Unit: A2UC146FA0 A2UH146FA0
A2UC186FA0 A2UH186FA0
A3UC216FA0 A3UH216FA0
A4UC306FA0 A4UH306FA0
• Indoor Unit: AMNC076LQL0 AMNH076LQL0
AMNC096LQL0 AMNH096LQL0/LQA0
AMNC126LRL0 AMNH126LRL0
AMNC186LTL0 AMNH186LTL0
AMNC246LTL0 AMNH246LTL0/LTA0
AMNC096AP*1 AMNH096AP*1
AMNC126AP*1 AMNH126AP*1

Questions and Answers

Summary

Safety Precautions

Installation

Covers crucial installation steps and safety warnings for the unit.

Operational

Details critical safety instructions for unit operation and usage.

Details of LG Model Name

Outdoor Unit

Explains the naming convention and structure of outdoor unit model numbers.

Indoor Unit

Explains the naming convention and structure of indoor unit model numbers.

Product Specifications

Outdoor_Heat Pump

Provides detailed technical specifications for outdoor heat pump models.

Outdoor_Cooling Only

Provides detailed technical specifications for outdoor cooling-only models.

Indoor_Heat Pump

Provides detailed technical specifications for indoor heat pump models.

Indoor_Cooling Only

Provides detailed technical specifications for indoor cooling-only models.

Combination Table

A2 UH146 FA0

Shows cooling and heating capacity combinations for A2UH146FA0 models.

A2 UH186 FA0

Shows cooling and heating capacity combinations for A2UH186FA0 models.

A3 UH216 FA0

Shows cooling and heating capacity combinations for A3UH216FA0 models.

A4 UC306 FA0

Shows cooling capacity combinations for A4UC306FA0 models.

Dimensions

Indoor Unit

Provides dimensional drawings and measurements for various indoor unit chassis.

Outdoor Unit

Provides dimensional drawings and measurements for outdoor unit models.

Refrigeration Cycle Diagram

A2 UH146 FA0

Illustrates the refrigeration cycle for the A2UH146FA0 outdoor unit.

A2 UC146 FA0

Illustrates the refrigeration cycle for the A2UC146FA0 outdoor unit.

A2 UH186 FA0

Illustrates the refrigeration cycle for the A2UH186FA0 outdoor unit.

A2 UC186 FA0

Illustrates the refrigeration cycle for the A2UC186FA0 outdoor unit.

A3 UH216 FA0

Illustrates the refrigeration cycle for the A3UH216FA0 outdoor unit.

A3 UC216 FA0

Illustrates the refrigeration cycle for the A3UC216FA0 outdoor unit.

A4 UH306 FA0

Illustrates the refrigeration cycle for the A4UH306FA0 outdoor unit.

A4 UC306 FA0

Illustrates the refrigeration cycle for the A4UC306FA0 outdoor unit.

Wiring Diagram

Indoor Unit

Details the internal wiring connections and diagrams for indoor units.

Outdoor Unit

Details the internal wiring connections and diagrams for outdoor units.

Electronic Control Device

Indoor Unit

Shows the layout and components of indoor unit electronic control PCBs.

Outdoor Unit

Shows the layout and components of outdoor unit electronic control PCBs.

Schematic Diagram

Indoor Unit

Presents detailed electrical schematic diagrams for indoor units.

Outdoor Unit

Presents detailed electrical schematic diagrams for outdoor units.

Functions

Indoor Unit

Describes the various functions and operational modes of the indoor unit.

Remote Controller

Explains the operation, buttons, and functions of the remote controller.

Signal Receptor

Details the signal reception and operation indication lamps on the unit.

Self-diagnosis Function

Explains error codes, indicators, and self-diagnosis capabilities.

Operation Details

Main Unit Functions

Details basic operational modes, indicators, and H/P specific functions.

Operational Modes and Features

Explains Fuzzy, Timers, Chaos, Jet Cool, Forced, Test, and Cleaner operations.

System Control and Protection

Covers remote control, frosting protection, and buzzer sound operations.

2-way, 3-way Valve

Pumping down

Provides the procedure for pumping down the refrigeration system.

Evacuation

Provides the procedure for evacuating the refrigeration system.

Gas Charging

Provides the procedure for charging refrigerant into the system.

Cycle Troubleshooting Guide

Trouble analysis

Analyzes common refrigeration cycle issues based on temperature difference.

Comp basic step

Details compressor operating steps and maximum capacity combinations.

Electronic Parts Troubleshooting Guide

Outdoor Unit does not operate at all

Troubleshooting steps for when the outdoor unit fails to operate.

Product is not operate with the remote controller

Troubleshooting steps for remote control operational issues.

When cooling does not operate

Troubleshooting steps when the cooling function is not working.

When Heating does not operate

Troubleshooting steps when the heating function is not working.

When indoor Fan does not operate

Troubleshooting steps for indoor fan operational failures.

When Vertical Louver does not operate

Troubleshooting steps for vertical louver movement issues.

Disassembly of the parts (Indoor unit)

SQ;SR;ST Chassis

Step-by-step guide for disassembling SQ/SR/ST chassis indoor units.

SP1 Chassis

Step-by-step guide for disassembling SP1 chassis indoor units.

Exploded View & Replacement Parts List

Indoor Unit

Provides exploded views and part numbers for indoor unit components.

Outdoor Unit

Provides exploded views and part numbers for outdoor unit components.

LG A4UH306FA0 Specifications

General IconGeneral
Voltage (V)220-240
Airflow Rate1200 m³/h
Phase1
Hertz (Hz)50
Operating Temperature (Cooling)18°C to 43°C
Operating Temperature (Heating)-15°C to 24°C
Air Flow (Indoor)1200 m³/h