Part 2 Functions & Controls
5.12 Low Ambient control
If outdoor temperature drops below certain temperature, liquid back is prevented by reducing fan speed.
It can prevent frosting of evaporator and keep cooling operation
No matter even if the outdoor temperature reaches -10°C.
You can Cool your room at your desired temperature all your around.
5.13 Test Operation (Cooling)
Press the Tact Switch for compulsory operation of the main body for 3 seconds in order to operate the unit in the trial
operation mode.
- Operation mode: Cold
- Indoor pan: Strong wind
- COMP frequency: Step 5
- COMP compulsorily operates for about 18 minutes irrespective of indoor temperature.
Freq.
- 0°C
°
Outdoor temp.
Outdoor pipe temp.
0°C outdoor fan On/Off
control
°
Comp Freq.
Outdoor fan
On
On
Off
Off
Outdoor temp.:-10°C
-5
0
5
10
15
20
25
0 50 100 150 200
Time(Min.)
Temp.(°C)
Outdoor fan On/Off control
Cond . temp.