5RMG0-02A
General Wall Mounted-50Hz(R410A/R407C)
Room Air Conditioners

Other manuals for LG AS-C126RLA0

Questions and Answers:

LG AS-C126RLA0 Specifications

General IconGeneral
Power Supply220-240V, 50Hz
Energy Efficiency Ratio (EER)3.21
Coefficient of Performance (COP)3.61
RefrigerantR410A
Indoor Unit Weight9 kg
Outdoor Unit Weight30 kg
Compressor TypeRotary
Star Rating3 Star
TypeSplit
Cooling Capacity3.5 kW

Summary

Models Line up

Model Number Nomenclature

Features & Benefit

NEO-Plasma Air Purifying System

LG's unique neo-plasma air purifying system with 12-level bio-enzyme filters for enhanced sterilization.

Nano Bio Fusion Filter

Filters that use nano-size bio enzymes to penetrate cell walls of bacteria and allergens.

Plasma Filter

Purifying system that removes micro contaminants, dust, and allergens.

Nano Carbon Filter

Filters that catch fine odorous particles and remove odors.

Pre Filter

Antibacterial pre-filters that remove large dusts, molds, and quilt dusts.

Triple Filter

Consists of organic-compound filter, formaldehyde filter, and odor filter.

Healthy Dehumidification

Dehumidification mode to remove uncomfortable humidity without over-cooling.

Auto Clean

Automatic cleaning function to dry the wet heat exchanger to prevent mold and bacteria.

Ultra Silent Operation

Low-noise operation for indoor and outdoor units for a quieter environment.

Anti Rust Gold Fin Protection

Gold-coated aluminum heat exchanger surface for corrosion resistance.

Auto Changeover

Automatic switching between cooling and heating based on setting temperature.

Low Ambient Cooling

Ability to cool the room even in winter conditions.

Hot Start Function

Prevents cold air blowing in heating mode by delaying indoor fan operation.

Auto Restart Function

Automatically sets A/C to previous settings after power failure.

Sleep Mode Auto Control

Programs unit for comfortable sleep by controlling fan speed and temperature.

Optimized Airflow

Twin air vanes for horizontal cooling and downward heating airflow.

New Chaos Swing Airflow

Mimics natural airflow for comfortable distribution, minimizing temperature differences.

Even & Fast Airflow

Improves temperature difference between high and low indoor temperatures for faster reach.

Jet Cool Function

Allows quick cooling by blowing strong, cool air at high speed for 30 minutes.

ARTCOOL Design Series

Aesthetic models including Mirror, Panel, and Wide types for interior design integration.

Modern & Luxury Design

Premium designs that match well with any part of the household.

Ez-Replaceable Color Panel

Allows changing air conditioner color to match background colors or interior design.

Digital Air Flow Control

Controlling airflow for comfort and convenience (Normal, Jet Cool, Sleep Mode).

Ultra Thin Design

Super slim design with 129mm depth, claimed slimmest in the world.

3 Dimensional Air Flow

3D airflow concept for even cooling and quick cooling from front and both sides.

DC Inverter Technology

Economical operation through energy saving and recouping initial investment costs.

Specifications

Dimensional Drawings

Indoor Unit Dimensions (SW, SQ, SR, ST)

General Wall Mounted (5~24k Btu.), SW, SQ, SR, ST dimensions.

Indoor Unit Dimensions (S4, S5)

General Wall Mounted (7~24k Btu.), S4, S5 dimensions.

Indoor Unit Dimensions (SM, SN)

General Wall Mounted (30~36k Btu.), SM chassis and SN chassis dimensions.

Outdoor Unit Dimensions (UA3)

7~12k Btu outdoor unit dimensions for UA3 chassis.

Outdoor Unit Dimensions (UL)

9~12k Btu outdoor unit dimensions for UL chassis.

Outdoor Unit Dimensions (UD)

18k Btu outdoor unit dimensions for UD chassis.

Outdoor Unit Dimensions (UM)

18~24k Btu outdoor unit dimensions for UM chassis.

Outdoor Unit Dimensions (UE)

18~24k Btu outdoor unit dimensions for UE chassis.

Outdoor Unit Dimensions (UE1)

24~30k Btu outdoor unit dimensions for UE1 chassis.

Outdoor Unit Dimensions (UE2)

36k Btu outdoor unit dimensions for UE2 chassis.

Wiring Diagrams

Indoor Units Wiring Diagrams (5~24k Btu)

Wiring diagrams for General Wall Mounted C/O and H/P units (5~24k Btu).

Indoor Units Wiring Diagrams (S4, S5)

Wiring diagrams for General Wall Mounted C/O and H/P units (5~24k Btu), S4, S5.

Indoor Units Wiring Diagrams (30/36k Btu)

Wiring diagrams for General Wall Mounted C/O, H/P (30/36k Btu.) units.

Outdoor Units Wiring Diagrams (5~9k Btu)

Wiring diagrams for Single Split C/O and H/P units (5~9k Btu).

Outdoor Units Wiring Diagrams (9~12k Btu)

Wiring diagrams for Single Split C/O and H/P units (9~12k Btu).

Outdoor Units Wiring Diagrams (18~24k Btu)

Wiring diagrams for Single Split C/O and H/P units (18~24k Btu).

Outdoor Units Wiring Diagrams (18~24k Btu H/P)

Wiring diagrams for Single Split H/P units (18~24k Btu).

Outdoor Units Wiring Diagrams (30k Btu C/O)

Wiring diagrams for Single Split C/O and H/P units (30k Btu).

Outdoor Units Wiring Diagrams (30k Btu H/P)

Wiring diagrams for Single Split C/O and H/P units (30k Btu).

Refrigerant Cycle Diagram

Model: Cooling Only

Diagram showing refrigerant flow for cooling-only models.

Model: Cooling and Heating

Diagram showing refrigerant flow for cooling and heating models.

Performance Data

General Wall Mounted-Cooling

Cooling performance data tables for various indoor/outdoor temperature conditions.

General Wall Mounted-Heating

Heating performance data tables for various indoor/outdoor temperature conditions.

Coefficient of Capacity Change

Model: 5K~24K Btu Cooling Only

Capacity change coefficients based on height and total pipe length.

Model: 5K~12K Btu Heat Pump

Capacity change coefficients for heat pump models based on height and pipe length.

Model: 18K~24K Btu Heat Pump

Capacity change coefficients for heat pump models based on height and pipe length.

Piping length and elevation

Details pipe sizes, standard length, elevation, and additional refrigerant requirements.

Operation Limits

Air Velocity and Temperature Distributions(Reference Data)

General Wall Mounted 7k Btu.

Cooling and Heating air velocity and temperature distribution charts for 7k Btu models.

General Wall Mounted 9k Btu.

Cooling and Heating air velocity and temperature distribution charts for 9k Btu models.

General Wall Mounted 12k Btu.

Cooling and Heating air velocity and temperature distribution charts for 12k Btu models.

General Wall Mounted 18k Btu.

Cooling and Heating air velocity and temperature distribution charts for 18k Btu models.

Function of Remote Controller

Type 1 (Wireless LCD)

Description of buttons and functions for wireless LCD remote control Type 1.

Type 2 (Wireless LCD)

Description of buttons and functions for wireless LCD remote control Type 2.

Type 3 (Wireless Simple)

Description of buttons and functions for wireless simple remote control Type 3.

Type 4 (Wireless Simple)

Description of buttons and functions for wireless simple remote control Type 4.

Related product manuals