Troubleshooting Guide
9K / 12K
4
Heat-sink TH. is damaged(short or open).
Heat-sink Temp. is over 95°C
Damage or defect on the sensing circuit of outdoor pcb assembly.
(R01H, R02H, C01H)
Heat-sink Temp. is over
95°C
Heat-sink TH.
is open or short
Heat-sink TH. in INV-IC is
Right ?
Sensing circuit of outdoor
pcb is right ?
YES
No
Check heat-sink TH.
- Measure resistance of TH.
(about 10k at 25 °C)
Heat-sink TH is connected to
outdoor PCB assembly?
YES
No
- Connect to CN-TH2 in
outdoor PCB assembly
No
- Check soldering state of
R01H, R02H, C01H
Check flow
Description Cause of error