EasyManua.ls Logo

LG ATNH186ELCA - Electrical Wiring Connections

LG ATNH186ELCA
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
Service Manual 67
4. Wiring Connection
Terminal Block of Outdoor Unit
1(L) 2(N) 3 4 5 1(L) 2(N) 3 4 5
Terminal Block of Outdoor Unit
1(L) 2(N) 3 4 5
Terminal Block of Indoor Unit
Terminal Block of Indoor Unit
POWER INPUT
RS T N
POWER INPUT
RS T N
1(L) 2(N) 3 4 5
3Phase
Heat Pump Model.
3Phase
Cooling Model Only.
The power cord connected to the outdoor unit
should be complied with the following specifications
(Rubber insulation, type H05RN-F approved by HAR
or SAA).
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
The connecting cable connected to the indoor and
outdoor unit should be complied with the following
specifications (Rubber insulation, type H05RN-F
approved by HAR or SAA).
CAUTION
8.5mm
20mm
GN/YL
7.5mm
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
2
(18K/24K/30K)
1.25mm
2
(36k/48k/45k)
Capacity 1 Phase 3 Phase
18, 24, 30k
BTU/h
36K BTU/h
48, 54K BTU/h
2.5mm
2
-
5.5mm
2
2.5mm
2
- 3.5mm
2
POWER
INPUT
1(L) 2(N) 4(N) 5 6 7 83(L)
4(N) 5 6 73(L)
Terminals on the indoor unit
Terminals on the outdoor unit
1Phase
Heat Pump Model.
1Phase
Cooling Model Only.
POWER
INPUT
Terminals on the indoor unit
1(L) 2(N) 4(N) 5 7683(L)
Terminals on the outdoor unit
4(N) 5 6 73(L)
Make sure that the screws of the terminal are free from looseness.
WARNING
1. All wiring must comply with LOCAL REGULATIONS.
2. Select a power source that is capable of supplying the current as required by the air conditioner.
3. Feed the power source to the unit via a distribution switch board designed for this purpose.
4. The terminal screws inside the control box may be loose due to vibration during transport.
Check the screws for loose connection.
(Running the air conditioner with loose connection can overload and damage electrical components.)
5. Always ground the air conditioner with a grounding wire and connector to meet the LOCAL REGULATION.