Connecting the cable to Outdoor Unit
• Remove the side panel for wiring connection.
• Use the cord clamp to fix the cord.
• Earthing work
- Case 1 :Terminal block of Outdoor Unit have mark.
Connect the cable of diameter 1.6mm
2
(15AWG) or more to the earthing terminal provided in the control box and do earthing.
- Case 2 :Terminal block of Outdoor Unit don't have mark.
Connect the cable of diameter 1.6mm
2
(15AWG) or more, to the panel of control box, marked as and fasten with earth screw.
h Please check !!
* Make sure the rubber bushes are
Properly used in knock-out holes after
connecting main Power cable
Connecting cable terminal
Power cord terminal
Cord clamp
Cord clamp
• The circuit diagram is not subject to change without notice.
• Be sure to connect wires according to the wiring diagram.
• Connect the wires firmly, so that not to be pulled out easily.
• Connect the wires according to color codes by referring the wiring diagram.
CAUTION
2. Guideline for each installation process
26 _ Heat pump 60Hz/R410A
Installation of
Outdoor Units
SINGLE ZONE