54 _ Heat pump 60Hz/R410A
4. Installation of outdoor unit
Installation of
Outdoor Units
SINGLE ZONE
4.4 Settlement of the outdoor unit
Anchor the outdoor unit with a bolt and nut tightly and horizontally on a concrete or rigid mount.
When installing on the wall, roof or rooftop, anchor the mounting base securely with a nail or wire assuming the influence
of wind and earthquake.
In the case when the vibration of the unit is conveyed to the house, secure the unit with an anti-vibration rubber.
Bolt construction work
Bolt
Tubing connection
M10
Mechanical anchor bolt
60(2-3/8)~120
(4-23/32)mm(inch)
20(25/32)mm(inch)
Diagram of lower surface
Settlement draw of outdoor units
• The ingredients of foundation : Cement : Sand : Gravel for the concrete should 1 : 2 : 4 ratio
• The foundation surface should be finished with mortar.
• The edges of foundation should be rounded.
• A drain passage should be made around the foundation to thoroughly drain water away from the equipment installation
area.
• If installing the outdoor units on the roof, the roof's strength have to be checked.
• Care should be taken for weather - proofing
• Blocking all gaps of outdoor unit, for passing piping and wiring, using sealing material (Field supply)
(Animals and bugs might enter in the machine.)