120 Synchro Air Conditioner
Troubleshooting Guide
Troubleshooting CH26, CH27
E
C
B
E
C
B
E
C
B
26
27
DC Compressor
Position
PSC Fault
Compressor
position detect error
Over current at IGBT
Check the connection of comp wire U,V,W
Malfunction of compressor
Check the component of IPM, detection parts.
Check the component of IGBT .
Check the components.
Display
code
Title Cause of error Check point & Normal condition
Check Point
CH 26
1. Check the connection of U,V,W
2. Check the insulation of IPM part.
3. Check the compressor. (same with CH21)
CH 27
1. Check the component of IGBT
2. Check the components
(IGBT, R04S, NF1, BD02S)