6
INSTALLATION OF OUTDOOR UNIT
ENGLISH
- If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that
heat radiation from the condenser is not restricted.
- Ensure that the spaces indicated by arrows around front, back and side of the unit.
- Do not place animals and plants in the path of the warm air.
- Take the air conditioner weight into account and select a place where noise and vibration are
minimum.
- Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.
Unit : mm
Installation Places
MODEL CAPACITY
Pipe Size Length A (m) Elevation B (m)
Additional
Refrigerant
(g/m)
Gas Liquid Standard Max. Standard Max.
AUUQ18GH2 5kW Ø12.7(1/2) Ø6.35(1/4) 5 30 5 15 20
AUUQ24GH2 7kW Ø15.88(5/8) Ø9.52(3/8) 5 50 5 30 20
AUUQ36GH2 10kW Ø15.88(5/8) Ø9.52(3/8) 5 50 5 30 20
AUUQ48GH2 13.4kW Ø15.88(5/8) Ø9.52(3/8) 5 50 5 30 20
AUUQ54GH2 15.8kW Ø19.05(3/4) Ø9.52(3/8) 5 50 5 30 20
Free Joint Single Outdoor
Piping length and the elevation
INSTALLATION OF OUTDOOR UNIT