24 Air-to-Water Heat Pump
Using Thermostat
Emergency Operation
• Definition of terms
- Trouble : a problem which can stop system operation, and can be resumed temporally under
limited operation without certificated professional's assist.
- Error : problem which can stop system operation, and can be resumed ONLY after certificated
professional's check.
- Emergency mode : temporary heating operation while system met Trouble.
• Objective of introducing 'Trouble'
- Not like airconditioning product, Air-to-Water heat pump is generally operation in whole winter
season without any system stopping.
- If system found some problem, which is not critical to system operating for yielding heating
energy, the system can temporarily continue in emergency mode operation with end user's
decision.
• Classified Trouble
- Trouble is classified two levels according to the seriousness of the problem. : Slight Trouble and
Heavy trouble
- Slight Trouble : Sensor trouble. In most case, this trouble is concerned with sensor problems. The
unit is operating under emergency mode operation(level 1).
- Heavy trouble : Compressor cycle trouble. Emergency mode operation(level 2) is performed by
optional electric heater.
- Option Trouble : a problem is found for option operation such as water tank heating. In this
trouble, the troubled option is assumed as if it is not installed at the system.
• Emergency operation level
- When system met trouble, it stops operation and wait for userʼs decision : Calling service center
or starting emergency operation.
- To start emergency operation, user simply push ON / OFF button once more.
- Two different levels are prepared for emergency operation : High temperature cycle and low
temperature cycle.
- In emergency operation mode, user can not adjust target temperature.
※ It can not be operated, if the electric heater accessory is not installed.
High temperature cycle OFF 50°C 24°C 70°C
Low temperature cycle ON 30°C 19°C 50°C
DIP
Switch
Target
Leaving Water
Temperature
Target
Room Air
Temperature
Target
Sanitary Water
Temperature

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG CH Series and is the answer not in the manual?

LG CH Series Specifications

General IconGeneral
RefrigerantR410A
Air Flow (Outdoor Unit)Varies by model
Dimensions (Indoor Unit)Varies by model
Dimensions (Outdoor Unit)Varies by model
Weight (Indoor Unit)Varies by model
Weight (Outdoor Unit)Varies by model
Air Flow (Indoor Unit)Varies by model
Wi-Fi CapableOptional
Smart FeaturesLG ThinQ app compatibility
Warranty1 year
Operating Temperature (Cooling)64°F - 95°F

Related product manuals