INSTALLATION
ENGLISH
Method 1
When the drain hose is connected to a waste
spigot, the hose must be looped up to the
underside of the bench top and secured.
Method 2
When the drain hose is connected to a separate
standpipe
a
, it is essential that an airtight
connection
b
be made. If not, it can induce odours.
• Standpipe diameter is at least 40 mm.
Preparing Water and
Electrical Connections
Connecting the Hose to the
Water Tap
Connect the water supply hose
a
to the water tap.
WARNING
Do not shorten or damage the water supply hose
as it contains electrical wires and components. It
can not be detached or removed from the
appliance for installation purposes.
It is important that the water supply hose not be
tampered with, cut, disassembled, pulled, or
kinked. It contains electrical wiring inside and if
damaged, can cause an electrical hazard.
CAUTION
Only use the threaded nut of the water supply
hose to tighten it to the tap.
Do not twist or kink the water supply hose when
connecting it to the tap.
This appliance may be fed with either hot or cold
water. If the water connection can not be
maintained below 65ºC, the appliance must be
connected to cold water.