EasyManua.ls Logo

LG DHB1260PL User Manual

LG DHB1260PL
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
P/No.: 3828A20114D Printed in Korea
P/No.:3828A20091C
Printed in China
DHB-1260PL-표지영어 2003.10.24 3:7 PM 페이지1

Questions and Answers:

LG DHB1260PL Specifications

General IconGeneral
BrandLG
ModelDHB1260PL
CategoryDehumidifier
LanguageEnglish

Summary

Safety Precautions

Electrical Safety

Warnings and cautions regarding safe use of the power cord and electrical connections.

Physical Safety

Precautions against injury from moving parts and inserting objects into the unit.

Symbol Guide

Explanations for warning and prohibition symbols used in the manual.

Names and Functions of Parts

Front View Components

Identifies and describes components located on the front of the dehumidifier.

Rear View Components

Identifies and describes components located on the rear of the dehumidifier.

Control Panel Overview

Explains the buttons, indicators, and modes of the control panel.

Control Panel Indicators

Details the meaning of different indicator lamps on the control panel.

How to Use

Operating Environment and Setup

Specifies operating temperature, ventilation, and initial setup steps.

Basic Operation Steps

Guides on connecting power, turning on, setting humidity, and mode conversion.

Airflow Adjustment

Instructions on using the Louver and Auto Swing button for airflow control.

Stopping Operation

How to turn off the unit using the ON/OFF button.

Mode Conversion

Automatic Dehumidification Mode

Details automatic dehumidification for clean air and humidity control.

Quiet Operation Mode

Explains the quiet operation mode with low fan speed.

Prevention Moisture Condensation Mode

Describes mode to prevent dew in low room temperatures.

Air Purifying Mode

Explains air purifying mode for cleaning contaminated air.

Spot Dry

Spot Dry Hose Usage

Steps for using the hose to direct dried air for targeted drying.

Activating Spot Dry

How to press the Spot Dry button and what happens next.

Extension Hose Warning

Guidance on using an extension hose and related warnings.

Laundry Dry Continuous/AUTO Swing

Laundry Dry Continuous Operation

How to use the unit for non-stop laundry drying.

AUTO Swing Operation

How to adjust airflow direction using the Louver and Auto Swing button.

Defrost Operation/FULL Mark/Timer/Humidity Setting

Defrost Operation and Indicators

Explains the automatic defrosting process and related indicators.

Water Full Indicator

Describes what happens when the water bucket is full and the indicator light.

Operating the Timer

Instructions on setting and cancelling the timer function.

Humidity Setting

How to set the desired humidity level for automatic operation.

Removing Collected Water

Bucket Removal and Emptying

Steps for removing the bucket, pouring water, and wiping it dry.

Proper Bucket Replacement

Ensures the bucket is correctly positioned for the unit to operate.

Bucket Maintenance Cautions

Important cautions for handling the bucket and cleaning the unit.

Continuous Drainage

Continuous Drainage Precautions

Warnings and conditions for using the continuous drainage feature.

Connecting the Drain Hose

Steps for connecting the hose to the continuous drainage hole.

Transporting the Unit

Instructions on how to safely move the dehumidifier using its caster.

Normal Maintenance

Cleaning Air Filter

Instructions for cleaning the air filter every two weeks.

Deodorizing Air Purifying Filter

Guidance on handling the deodorizing filter and its replacement.

Installing Air Filter

Steps to correctly install the air filter after cleaning or replacement.

Long-term Storage

Storage Preparation Steps

Steps to unplug, remove water, and clean the filter before storage.

Filter Drying and Storage

How to dry and store the filter properly for long-term storage.

Troubleshooting

Dehumidifier Not Starting

Checks for issues when the operation buttons are pressed but the unit doesn't start.

Low Moisture Removal

Reasons for small amounts of moisture being removed, like clogged filters or wrong modes.

Ineffective Dehumidification

Explains why the unit might not be drying air effectively, like open windows or large areas.

Humidity Reading Discrepancies

Notes that humidity readings may differ based on location.

Fan Noise Issues

Possible causes for fan noise, such as unstable floor or clogged filter.

Laundry Drying Issues

Reasons why laundry may not be drying properly, like poor air contact or too much laundry.

Alternating Operation

Explains when operation repeats alternately, possibly due to AUTO mode.

Water Leaks

Potential causes for water leaks, such as unit skewing or hose connection issues.

Normal Operating Symptoms

Compressor Delay and Auto-Shutoff

Explains compressor delay and auto-shutoff when humidity is met.

Sudden Noise Increase During Operation

Describes noise increase when the compressor starts or in AUTO mode.

Variable Noise Volume

Notes that noise volume changes with Louver angle.

Weird Sounds During Operation Startup/Stop

Mentions sounds from coolant circulation stabilization.

Initial Smell in Wind

Explains temporary smell due to heat exchanger temperature increase.

Warm Wind Output

Clarifies that warm wind is normal as there's no cooling function.

Abnormal Louver Angle Correction

Suggests pressing AUTO Swing button again for abnormal Louver operation.

Normal Bucket Marks

Explains that factory test water or evaporation traces in the bucket are normal.

Related product manuals