EasyManua.ls Logo

LG DLE3777W - Test 3: Motor Resistance Check

LG DLE3777W
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
Test 3
Motor test
Caution
Trouble Symptom
Measurement Condition
Before measuring resistance, be sure to turn Power off, and do voltage discharge.
(When discharging, contact the metal plug of Power cord with earth line.)
Drum will not rotate; No fan will function; No Heater will work.
Turn the Dryers Power Off, then measure resistance.
Is resistance below 1 between Idler Switch
terminals?
YES
NO
Does Idle Switch attached to Motor Bracket
operate Level by drum belt?
(Not operating Lever is normal.)
YES
Replace Idler
Switch.
Check Idler Assembly.
Drum Belt cuts off
Drum Belt takes off
from
Motor Pulley.
Is resistance below 3 between Connector
WH3-
(White wire) and BL2- (Yellow wire)?
Measure while door is closed.
YES
NO
Check if Door flame
presses door switch
knob.
Check Door Switch.
Check Harness
connection.
Is resistance below 3 between Connector
BL2-
(Yellow wire) and BL2- (Brown wire)?
NO
YES
Replace Control.
(Relay check)
Check Controller
connector.
Is resistance below 1 between terminals
of Outlet Thermostat attached to blower housing?
YES
NO
Replace Outlet
Thermostat.
(Refer to
Component)
Is resistance below 3 between Connector
WH3-
(White wire) and BL2-
(Brown wire)?
Measure while door is closed.
NO
YES
Replace Control.
(Relay check)
Check Controller
connector.
Check Motor.
(Refer to Motor Diagram & Check)
Check if Control Connector is contacted.
Idler Switch Lever
Idler Switch

Related product manuals